00041446.DOC, Version 1.0
42/60
The Moving-Head can be placed directly on the stage floor or rigged in any orientation on a truss without
altering its operation characteristics (see the drawing).
The fixture’s base enables to be
mounted in two ways.
For overhead use (mounting
height >100 cm), always install
an appropriate safety bond.
You must only use safety bonds
complying with DIN 56927, quick
links complying with DIN 56926,
shackles complying with DIN EN
1677-1 and BGV C1 carbines.
The safety bonds, quick links,
shackles and the carbines must
be sufficiently dimensioned and
used correctly in accordance with
the latest industrial safety
regulations (e. g. BGV C1, BGI
810-3).
Please note:
for overhead
rigging in public or industrial
areas, a series of safety
instructions have to be followed
that this manual can only give in
part. The operator must therefore inform himself on the current safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Install the safety bond by inserting the quick link in the hole on the bottom of the base Pull the safety bond
over the trussing system etc. Insert the end in the quick link and tighten the fixation screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!