00062987.DOC, Version 1.0
27/36
Connection between devices
On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Please note:
A maximum of 8 devices may be linked together. After every 8 devices,
the fixtures must have a renewed connection with the power mains.
OPERATION
After you connected the effect to the mains, the PCT-3200 starts running. During the reset, the motors are
trimmed and the device is ready for use afterwards.
Stand Alone operation
In the Stand Alone mode, the PCT-3200 can be used without controller.
Disconnect the PCT-3200 from the controller and call the internal program.
1. Press
[MODE/ESC]
button to enter the main menu
"MODE"
(display flashing)
2. Press
[ENTER]
and select
“RUN”
by pressing
[UP]
button.
3. Press
[ENTER]
and select
“AUTO”
by pressing
[UP]
button.
4. Press
[ENTER]
and select
“ALONE”
by pressing
[UP]
button.
5. Press
[ENTER]
to confirm, the display shows
“AU-A”
.
Please refer to the instructions under Control Board, Main functions, menus Mode and Edit.
DMX-controlled operation
You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.