There are a number of LEDs 

which will light up when the

corresponding contact closure 

connections are shorted together.

A red LED will light up when the

emergency stop link is removed.

Sheet 5 of 7

ISSUE:  004 

www.futureautomation.co.uk

FUTURE

AUTOMATION

SU / CME 

Swivel Unit

Instruction Sheet

PIN

568

B

568

A

DESCRIPTION

ACTION

1

2

3

4

5

6

7

8

W/G

G

W/O

BL

W/BL

O

W/BR

BR

W/O

O

W/G

BL

W/BL

G

W/BR

BR

12V SUPPLY  CURRENT LIMITED

12V TRIGGER

GROUND

DEVICE TOGGLE

DEVICE IN LATCHED

DEVICE STOP

DEVICE OUT

DEVICE IN

When 12V is attached, device will go OUT.

When 12V is removed, device will go IN.

Momentary short to ground will switch the

device between states of IN / OUT.                CC5
When shorted to ground, device will go OUT.

When short removed, device will go IN.         CC4

When shorted to ground,

stops device in current position.                     CC3

Momentary short to ground 

will make device go OUT.                              CC2
Momentary short to ground 

will make device go IN.                                  CC1

Contact Closure

Use an RJ45 connector in the 

CC1 socket on the control box 

to operate via contact closure.

 

Summary of Contents for TTR60

Page 1: ...1 Remote Control Your Pack Should Contain 1 Control Box Sheet 1 of 7 ISSUE 004 www futureautomation co uk FUTUREAUTOMATION SU CME Swivel Unit Instruction Sheet It is the responsiblity of the installe...

Page 2: ...sition to learnt position 6 HOME Takes screen to forward facing position when screen is already in an angled position 13 Rotates screen left 14 Rotates screen right 8 11 within 1sec Sets limits to 180...

Page 3: ...xample left shows the programming of a position that is left of centre In order to program a position that it right of centre simply press 14 to start rotating the screen anti clockwise Then press 3 t...

Page 4: ...1 2 1 Connect the Infrared Sensor here It is VERY important that when all of the electrical connections are made the connector blocks are connected in the way shown above with all the wires coming di...

Page 5: ...R 12V SUPPLY CURRENT LIMITED 12V TRIGGER GROUND DEVICE TOGGLE DEVICE IN LATCHED DEVICE STOP DEVICE OUT DEVICE IN When 12V is attached device will go OUT When 12V is removed device will go IN Momentary...

Page 6: ...E Swivel Unit Instruction Sheet RS232 Use an RJ11 connector in the socket marked RS232 on the control box to operate using RS232 DETAILS Band rate 9600 Stop bit 1 Parity None Databits 8 PROTOCOL ASCI...

Page 7: ...in CC1 Lit Hub alligned in central position CC2 Flashing Indicates position being counted EMERGENCY STOP This connection will stop all functions of the mechanism once broken removed Red LED will also...

Reviews: