COMMAND
ACTION
fa_in
Device Fully IN
fa_out
Moves Arm OUT, Head PARALLEL
fa_preset
Moves Arm to Recess Position, Head PARALLEL
fa_left
Moves Arm OUT, Rotates Head Fully LEFT
fa_right
Moves Arm OUT, Rotates Head Fully RIGHT
fa_d
Go to Viewing Angle D
fa_e
Go to Viewing Angle E
fa_f
Go to Viewing Angle F
fa_stop
STOPS Device at any position
fa_save-0
Store Viewing Angle 0
fa_save-1
Store Viewing Angle 1
fa_save-2
Store Viewing Angle 2
fa_save-3
Store Viewing Angle 3
fa_save-4
Store Viewing Angle 4
fa_save-5
Store Viewing Angle 5
fa_go-0
Go to Viewing Angle 0
fa_go-1
Go to Viewing Angle 1
fa_go-2
Go to Viewing Angle 2
fa_go-3
Go to Viewing Angle 3
fa_go-4
Go to Viewing Angle 4
fa_go-5
Go to Viewing Angle 5
Page 18 of 22 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
QA2 & QA2-60 - Quad Arm
In
st
all
at
io
n
:
R
S
23
2
IMPORTANT
Ensure protocol is entered exactly as written, including Carriage Return
(Enter / ASCII 13). After pressing STORE you have a 2 second window to
select your save button, after 2 seconds the command is void.
RS232
- Use an RJ25 connector in the socket marked
RS232 on the control box to operate using RS232
Details
Baud rate: 9600
Stop bit:
1
Parity:
None
Databits:
8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND
Pin 2: TX
Pin 3: RX
Pin 5: GROUND
RJ25
9 PIN D
PIN 1: RX
TO
PIN 2: TX
PIN 6: TX
TO
PIN 3: RX
PIN 3: GROUND
TO
PIN 5: GROUND
PIN 4: GROUND
TO
PIN 5: GROUND
SLQV