SLQV
Contact Closure
- Use an RJ45 connector in the CCI
socket on the control box to operate
via contact closure
LED 1
LED 2
LED 3
LED 4
LED 5
CONTACT CLOSURE
INPUT
Any contact closure input whilst
the mechanism is in motion will
stop the movement and all other
contact closure commands will
be disabled for 1 second.
568A
568B
1
12V SUPPLY
12V SUPPLY - CURRENT LIMITED
W/G
W/O
2
PIN 2 NOT USED
G
O
3
GROUND
GROUND
W/O
W/G
4
PIN 4 NOT USED
BL
BL
5
DEVICE LEFT
Momentary short to GROUND (pin 3), will
make device go LEFT.
W/BL
W/BL
LED 4
6
DEVICE RIGHT
Momentary short to GROUND (pin 3), will
make device go RIGHT.
O
G
LED 3
7
DEVICE HOME
Momentary short to GROUND (pin 3),
makes device go OUT / HOME.
W/BR
W/BR
LED 2
8
DEVICE IN
Momentary short to GROUND (pin 3),
makes device go IN.
BR
BR
LED 1
PIN
DESCRIPTION
ACTION
WIRE / CABLE
CONTACT CLOSURE
LED INDICATOR
In
st
all
at
io
n
:
C
on
ta
ct
C
lo
su
re
Page 16 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSM S BE - Lift System Medium Swivel Box Enclosure