Future Automation FSE90 Installation Instructions Manual Download Page 12

In

st

al

la

ti

o

n

E

le

ct

ric

al

 c

on

ne

ct

io

n

Page 11 of 16 // email [email protected]  tel: +44 (0) 1438 833577  fax: +44 (0) 1438 833565

FSE90 Flat Screen Electric Wall Mount

Contact Closure

Use an RJ45 connector in the
CCI socket on the control box
to operate via contact closure

SLQV

LED 1
LED 2
LED 3

LED 4
LED 5

CONTACT CLOSURE INPUT

NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.

568A

568B

1

12V SUPPLY

12V SUPPLY - CURRENT LIMITED

W/G

W/O

2

12V LATCH

When 12V attached, device will go OUT to PRESET  

position. When 12V removed, device will go IN.

G

O

3

GROUND

GROUND

W/O

W/G

4

DEVICE LATCH

Short to GROUND (pin 3), device will go OUT to PRESET 

position, remove short device will go IN.

BL

BL

5

PIN 4 NOT USED

W/BL

W/BL

6

DEVICE STOP

Momentary short to GROUND (pin 3), stops device in 

current position.

O

G

7

DEVICE OUT

Momentary short to GROUND (pin 3), makes device go 

OUT.

W/BR

W/BR

8

DEVICE IN

Momentary short to GROUND (pin 3), makes device go 

IN.

BR

BR

PIN

DESCRIPTION

ACTION

WIRE / CABLE

Summary of Contents for FSE90

Page 1: ...577 fax 44 0 1438 833565 ISSUE 010 InstallationInstructions FSE90FlatScreenElectricWallMount Design Highlights Quiet Smooth Action with Variable Speed Motion Full Cable Management Stylish Look and Fin...

Page 2: ...can result in serious personal injury or damage to equipment Future Sound Vision trading as Future Automation intend to make this and all documentation as accurate as possible However Future Automatio...

Page 3: ...4 Package Contents 4 Stage 1 Screen Fitment 5 Before You Start Check 5 Stage 2 Vertical Height Alignment 6 Stage 3 Fitting The Mechanism To The Wall 7 Stage 4 Removing The Side Panel Cable Management...

Page 4: ...d by misuse or damage accidental or otherwise or service modification by persons not authorised by Future Automation or the use of any non Future Automation supplied parts Any electrical or other envi...

Page 5: ...echanism 1 1 Screen Mount Plate 1 2 Wall Mount Plate 1 3 Mechanism Cover 1 4 Link Arm 2 IR Remote Control Not Shown On Page 3 x2 AAA Batteries 4 Multi Pack Of Nut Bolts Washers 5 Mains Power Other Lea...

Page 6: ...suit your screen Further instructions relating to any custom mount will be included with the custom adapter When fitting the screen to the mechanism make sure that the centre of any adaptor plate is i...

Page 7: ...f 16 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 FSE90FlatScreenElectricWallMount Measure the distance from the top of the screen down to the top mounting hole on the w...

Page 8: ...e to the wall Fixings Fix through one of the top holes first Using the wall plate as a template mark the other holes before drilling into the wall Make sure a spirit level is used at all times to ensu...

Page 9: ...s through the mechanism Take off the side panel as shown by removing the four bolts 2 top and 2 bottom that hold it in place Remember to disconnect the power before removing the side panel Replace sid...

Page 10: ...enElectricWallMount Attach the screen to the mounting plate using the appropriate fixings found in the fixtures pack It may be necessary with some screens to use spacers to provide clearance for AV ca...

Page 11: ...options IN HOME PRESET A B C D E F OUT The FSE90 has standard preset positions linked to the buttons shown above The preset options are not active until the mechanism has gone fully IN and OUT If the...

Page 12: ...D indicators 568A 568B 1 12V SUPPLY 12V SUPPLY CURRENT LIMITED W G W O 2 12V LATCH When 12V attached device will go OUT to PRESET position When 12V removed device will go IN G O 3 GROUND GROUND W O W...

Page 13: ...positional counters Details Baud rate 9600 Stop bit 1 Parity None Databits 8 IMPORTANT Ensure protocol is entered exactly as written including Carriage Return Enter ASCII 13 After pressing STORE you...

Page 14: ...s the bracket fully out 90 to the wall In Brings the bracket fully in parallel to the wall Stop Will stop the operation at any position Preset Brings the bracket back out to the stored position Store...

Page 15: ...833565 FSE90FlatScreenElectricWallMount Wall Mount FSE90 Trouble shooting For information on our products please refer to our web site www futureautomation co uk or for questions on installations and...

Page 16: ...th 850mm 33 5 Control IR Remote RF Remote Contact Closure RS232 Power Supply 240V or 110V Control Of 3rd Party Product No Output Power Supply No Shipping Details Dimensions W D H 620x530x250mm 24 4x20...

Page 17: ...Page 16 of 16 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 FSE90FlatScreenElectricWallMount Notes...

Page 18: ...e Automation Unit 2 Kimpton Enterprise Park Claggy Road Kimpton Hertfordshire SG4 8HP United Kingdom Tel 44 0 1438 833 577 Fax 44 0 1438 833 565 Email info futureautomation co uk www futureautomation...

Reviews: