LEFT
A
B
C
D
E
F
RIGHT
PRESET
Mechanism Control
PRESET POSITIONS
Preset positions become active once the
mechanism has travelled fully LEFT and fully
RIGHT or a maximum LEFT limit is set.
To adjust presets press STOP in the desired
position then STORE and you’ll have a 2 sec
window to press PRESET or buttons A-F to
save that position to that particular button.
If the power is cut while the mechanism is
moving its position will need to be re-
referenced (see Mechanism Reset).
Until referenced, the mechanism will not be
able to access stored positions and will only
be able to move right in short pulses.
MECHANISM RESET
If the mechanism does not see one of the limit
switches for a long period of time its position
counting may lose accuracy.
To re-reference the position counting simply
send the mechanism to the RIGHT position.
If the full 120 sweep is not being used the
mechanism must be able to be sent to the
RIGHT limit (see Page 3 for details).
SETTING LEFT LIMIT
If the full 120 travel cannot be used because
of physical obstructions the LEFT limit can be
programmed by stopping the mechanism at
the desired position and pressing STORE then
LEFT.
This limit can be cleared by pressing STORE
then STOP then LEFT.
If the LEFT limit is set by the installer the
preset positions will be equally spaced
between this new travel sweep.