background image

Quick Start Guide

Sensor Solutions Source

Load · Torque · Pressure · Multi Axis · Calibration · Instruments · Software

www.futek.com

USB520

External USB Output Kit

Summary of Contents for USB520

Page 1: ...Quick Start Guide Sensor Solutions Source Load Torque Pressure Multi Axis Calibration Instruments Software www futek com USB520 External USB Output Kit...

Page 2: ...ecifications without notice Please visit www futek com termsandconditions for complete terms and conditions FUTEK Advanced Sensor Technology Inc 10 Thomas Irvine CA 92618 USA Tel 949 465 0900 www fute...

Page 3: ...nformation 5 Multiple Profile Selection in SENSIT 7 Supplied Voltage Selection in SENSIT 8 System Calibration in SENSIT 9 ASCII Streaming Output 10 Specifications 11 mV V Wiring Example 13 Amplified W...

Page 4: ...luded with the USB520 is one 12 pin male plug for use with a sensor and one 4 pin USB cable assembly for connections to a computer USB 2 0 port 12 PIN SENSOR CONNECTOR USB 2 0 HI SPEED A B CABLE 12 PI...

Page 5: ...Input Connections L PLEAD Leading pulse from sensor M PLAG Lagging pulse from sensor 12 PIN SENSOR CONNECTOR TO USB520 For 6 wire sensors connect Sense to Excitation and Sense to Excitation Note Sens...

Page 6: ...The 4 75V Output and Ground pins can be used to power circuits such as encoders in our rotary torque sensors The Leading Pulse and Lagging Pulse pins can be used with the Ground pin for encoder outpu...

Page 7: ...n and can be used for different types of sensors or the same sensor One way to utilize the multiple profiles is to improve the accuracy for the lower range of a sensor by having one profile for the fu...

Page 8: ...amplified sensors such as the FUTEK rotary torque line TRS605 In SENSIT supply voltage options can be accessed by right clicking on the Display Mode screen When changing to a default profile the supp...

Page 9: ...ons in the SENSIT calibration menu under the Calibration Settings The sensor output type does not have to be the same for each profile meaning the USB520 can be calibrated to multiple sensors with dif...

Page 10: ...n automatic streaming ASCII output of the current reading The ASCII output will turn off when the USB520 is in command mode such as when in use with SENSIT Resetting or unplugging and re plugging in t...

Page 11: ...NPUT Encoder Input Quadrature Leading and Lagging Pulse Speed Measurement Up to 150k pulses per second1 Angle Measurement up to 10k pulses per rotation PPR 1 GENERAL Internal Resolution 24 bits Output...

Page 12: ...ut Range 3 4 mV V factory default Optional Input Range 400 mV V Min Bridge Resistance 50 Ohm Max Bridge Resistance 5000 Ohm VOLTAGE INPUT Standard Input Range 10 VDC factory default CURRENT INPUT Stan...

Page 13: ...C L B A K J H mV V Wiring Example Bridge Sensor XXX Excitation Red Pin Signal Green Yellow Pin Signal White Pin Excitation Black Blue Pin 1 2 4 3 A B C D Note For sensors with Sense the sense wires mu...

Page 14: ...und Pin ENCODER CONNECTIONS Power Pin Power Ground Pin Signal Angle 1 Pin Signal Angle 2 Pin USB520 G M F E D C L B A K J H Amplified Output Wiring Example F H G L K M J G F E C D H B G E Note Encoder...

Page 15: ...A B CABLE WITH FERRITE CHOKES M M 6 FT Item Number GOD04123 BINDER MALE PLUG WITH CABLE CLAMP Item Number GOD02975 Programming Support FUTEK offers our USB DLL file as well as LabVIEW and Visual Basic...

Page 16: ...10 Thomas Irvine CA 92618 USA Tel 949 465 0900 www futek com...

Reviews: