Temperature (Type-K)
(probe accuracy not included)
+20.0 to 1000°C
± (3% + 5°C)
-4.0 to 1832°F
± (3% + 9°F)
∙ Accuracy is given as ±(% of r counts of least significant digit) at 23°C
±5°C, with relative humidity less than 80%RH. ac voltage and current shall be sub-
ject to sine wave.
GENERAL SPECIFICATIONS
Clamp size
opening approx. 35mm
TRMS
The AC voltage and AC current of this meter are meas-
ured by TRMS. True RMS measurement is different from
mean measurement. The mean measurement method
can only measure the symmetric waveform, such as sine
wave. True RMS measurements can reliably measure any
irregular waveform and obtain valid values for AC voltage
or AC curent.
Diode Test
Test current of 0.3mA typical.
Open circuit voltage 3.2V DC typical
Continuity heck
Threshold <=50Ω
test current <0.5mA
Overrange indication “OL” is displayed
Measurement rate
2 per second, nominal
Input impedance
10M (VDC and VAC)
Display
6000 counts LCD
AC Current
50-60Hz (AAC)
AC Voltage bandwith 50-400Hz (VAC)
Operating temperature 5 to 40°C
Storage temperature
-20 to 60°C
Operating humidity
Max. 80% up to 31°C decreasing linearly to 50% at 40°C
Storage humidity
<80%
Operating Altitude
2000 meters maximum
Over voltage
Category III 1000V
Auto off
Approx. 30 minutes
Safety
For indoor use and in accordance with Overvoltage
Category II, Pollution Degree 2. Category II includes local
level, appliance, portable equipment, etc., with transient
overvoltages less than overvoltage Cat. III.
Futech is a registered brand of Laseto NV, Belgium.
Futech declares that the Signaltester RJ-F
is in conformity with the following standards:
· EN 61010-1:2010
· EN 61010-031:2015
· EN 61010-2-032:2012
following the provisions of Directive:
· Low Voltage Directive 2014/35/EU
Tested by Shenzhen Huatongwei International Inspection Cr. Ltd., China
Certificate number CTSE20050097R1 - May 27, 2020