Futech AMPCLAMP 1000 Manual Download Page 6

Temperature (Type-K) 

(probe accuracy not included)

+20.0 to 1000°C

± (3% + 5°C)

-4.0 to 1832°F

± (3% + 9°F)

 ∙ Accuracy is given as ±(% of r counts of least significant digit) at 23°C 

±5°C, with relative humidity less than 80%RH. ac voltage and current shall be sub-

ject to sine wave.

GENERAL SPECIFICATIONS

Clamp size

opening approx. 35mm

TRMS

The AC voltage and AC current of this meter are meas-

ured by TRMS. True RMS measurement is different from 

mean measurement. The mean measurement method 

can only measure the symmetric waveform, such as sine 

wave. True RMS measurements can reliably measure any 

irregular waveform and obtain valid values for AC voltage 

or AC curent.

Diode Test

Test current of 0.3mA typical. 

Open circuit voltage 3.2V DC typical

Continuity heck

Threshold <=50Ω 

test current <0.5mA

Overrange indication “OL” is displayed
Measurement rate

2 per second, nominal

Input impedance

10M (VDC and VAC)

Display

6000 counts LCD

AC Current

50-60Hz (AAC)

AC Voltage bandwith 50-400Hz (VAC)
Operating temperature 5 to 40°C
Storage temperature

-20 to 60°C

Operating humidity

Max. 80% up to 31°C decreasing linearly to 50% at 40°C

Storage humidity

<80%

Operating Altitude

2000 meters maximum

Over voltage

Category III 1000V

Auto off

Approx. 30 minutes

Safety

For indoor use and in accordance with Overvoltage 

Category II, Pollution Degree 2. Category II includes local 

level, appliance, portable equipment, etc., with transient 

overvoltages less than overvoltage Cat. III.

 

Futech is a registered brand of Laseto NV, Belgium. 

Futech declares that the Signaltester RJ-F   

is in conformity with the following standards:

 · EN 61010-1:2010

 · EN 61010-031:2015

 · EN 61010-2-032:2012 

  

following the provisions of Directive:

 · Low Voltage Directive 2014/35/EU 

Tested by Shenzhen Huatongwei International Inspection Cr. Ltd., China 

Certificate number  CTSE20050097R1 -  May 27, 2020

Reviews: