background image

Thank you for purchasing a Futaba 

TMA-1

 Telemetry 

adapter. This 

TMA-1

 displays the telemetry data from 

a telemetry receiver on a tablet or smart phone. 

TMA-

1

 is connected on a tablet or smart phone. An exclusive 

application is downloaded to the tablet or a smart phone. 
Telemetry data can be seen more legible. 

Connection Method

Required

Connections and Name of Each Part of the TMA-1

Neither water nor fuel must adhere to TMA-1.

As with any electronic components, proper 

precautions are urged to prolong the life and 

increase the performance of the TMA-1. 

Do not use the TMA-1 with anything other than an 

R/C model.    

An operator must not look at a screen.    

You may loose sight of the aircraft during 

flight and this is extremely dangerous. Have an 

assistant on hand to check the screen for you.  A 

pilot should NEVER take his eyes off his aircraft.

WARNING

 

● Tablet or smart phone.

      The conditions of tablet or smart phone

● FASSTest or T-FHSS telemetry system transmitter and receiver .
● Telemetry sensor .

◆ USB to electric supply is possible. ◆ Dual core ◆ OS :Android 

™ 

3.2 ~

◆ Memory:RAM 1GB ~ ROM  16GB ~ ◆ Internet connectivity

Clip holder

OTG (USB On-The-Go) host cable

In Telemetry Receiver

In Telemetry Sensor

The selected Model 

TMA-1 Receiver and TMA-1 

are made to link.

The power supply of TMA-1 is supplied 

from tablet or smart phone.

It has the same setup of 

a sensor  slot  number 

in the transmitter. 

 FASSTest or T-FHSS receiver

The telemetry data of the 
altitude, temperature, etc. 
displays.

OTG host cable

The application of TMA-1 was installed in 
either your tablet or smart phone.

Telemetry Receiver(Option)

● Telemetry Receiver(Option)

SBS-01T,SBS-01TE(Temperature sensor)

SBS-01A(Altitude sensor)

SBS-01RM(Magnet type R.P.M sensor)

SBS-01RO(Optical type R.P.M sensor)

SBS-01G(GPS sensor)

SBS-01V(Voltage sensor)

(2014. 10)

The manual of the application 
of a TMA-1 and the application 
is downloaded from the WEB 
site of Futaba.

TMA-1 ratings

1M23N29802

TMA-1

Cover

Link button

LED

Instruction Manual

TMA-1

Telemetry Adapter

Applicable systems: Futaba FASSTest, T-FHSS Telemetry system

 

 

• Size: 2.69 x 1.21 x 0.46 in. (68.3 x 30.8 x 11.6mm)

• Weight: 0.54 oz. (15.4g)

• Current drain: 140mA or less

Summary of Contents for TMA-1

Page 1: ...er Telemetry sensor USB to electric supply is possible Dual core OS Android 3 2 Memory RAM 1GB ROM 16GB Internet connectivity Clip holder OTG USB On The Go host cable In Telemetry Receiver In Telemetry Sensor The selected Model TMA 1 Receiver and TMA 1 are made to link The power supply of TMA 1 is supplied from tablet or smart phone It has the same setup of a sensor slot number in the transmitter ...

Page 2: ... is pushed for a long time to LED blink 2 The transmitter is turned on and set to Link mode Receiver Link Jog button push 3 The link button of receiver is pushed for a long time to LED blink Completion of a link will change LED of TMA 1 green from red By linking the receiver and TMA 1 the data reception from a receiver becomes possible System Set of TMA 1 is chosen from FASSTest or T FHSS The rece...

Page 3: ... necessary to attach a sensor to the model according to the instruction manual of the telemetry sensor TMA 1 and telemetry receiver have to be linked according to the instruction manual a TMA 1 Turn OFF the Wi Fi function 2 4 GHz on the tablet or smart phone The display screen of this manual is an example of a tablet The display may change in part when a smart phone is used as compared to a tablet...

Page 4: ... tablet or smartphone Telemetry Receiver Option Telemetry Receiver Option SBS 01T SBS 01TE Temperature sensor SBS 01A Altitude sensor SBS 01RM Magnet type R P M sensor SBS 01RO Optical type R P M sensor SBS 01G GPS sensor SBS 01V Voltage sensor 2014 10 How to make TMA 1 app display that has telemetry sensor data on your tablet or smartphone The telemetry data such as altitude temperature and volta...

Page 5: ...ing Receiver Voltage Alert Temperature Setting Temperature Alert RPM Setting RPM Alert Altitude Setting Altitude Alert GPS Setting GPS Locus Setting Log 1 Start Data Logging 2 Check Log Data 3 Save Log Data Setting System Set Language About Table of contents 4 4 5 6 6 7 7 8 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 22 22 23 Start up TMA 1 ...

Page 6: ... Navigate to Setting About device Scroll to bottom Tap build number seven times You ll get a short pop up in the lower area of your display setting that you are now a developer 2 Enable USB Debugging How to call Developer Options with the tablet and smart phone to be used differs Please confirm by the tablet to be used or the manual of a smart phone Start up TMA 1 Visit Futaba WEB site www futaba ...

Page 7: ...een Tap Futaba TMA 1 icon Monitor Each telemetry sensor data can be displayed on the screen Log Record telemetry data System Set Select FASSTest or T FHSS in accordance with your radio system Monitor System Set Log ...

Page 8: ...streamlined approach see Page7 Signal level of the TMA 1 from a receiver can be checked by the signal level icon that is on the upper right of your screen It does not show the signal level from a transmitter to a receiver 1 Receiving Signal Level No signal Strong Weak Write Log ...

Page 9: ... Sensor Setting Add Page The title of the page can be changed as your preference Three kinds of display sizes can be chosen Tap Add Page Tap Tap Delete Page Deletion of the added page Write Log Page Title ...

Page 10: ...8 Sensor Setting Add a sensor on the page Delete a sensor from the page Initialize the page setting Long press button Servo Monitor Servo is chosen in device option ...

Page 11: ...n Setting Device Sensor or receiver voltage display item pushed for a long time this display will appear You can edit title name Select Sensor Select the sensor type Select sensor slot Select maximum value TMA 1 can display the receiver and external battery voltage ...

Page 12: ...age Alert High Low voltage alarm can be enabled with sound and red blink early screen Set receiver alarm Set external voltage alarm Set maximum value Set maximum value Set minimum value Set minimum value Alert Display ...

Page 13: ...e value of the temperature sensor Long press the button Setting Device Sensor or temperature display item pushed for a long time this display will appear You can edit title name Select Sensor Select Temperature Select maximum value Select the Unit or Select sensor slot ...

Page 14: ...12 Temperature Alert High Low temperature alarm can be enabled Alert Display Set Alarm Set maximum value Set minimum value ...

Page 15: ...nsor Long press the button Setting Device Sensor or RPM display item pushed for a long time this display will appear You can edit title name Select Sensor Select RPM Optics Number of fins Magnet Gear Ratio Select maximum value Select Types Optics or Magnet Select sensor slot ...

Page 16: ...14 RPM Alert High Low RPM alarm can be enabled Set Alarm Set maximum value Set minimum value Alert Display ...

Page 17: ...cordance with a transmitter it chooses the slot 1 5 8 13 16 21 24 29 Altitude is displayed TMA 1 can display Altitude sensor Long press the button Setting Device Sensor or Altitude display item pushed for a long time this display will appear You can edit title name Select Sensor Altitude is chosen Select altitude unit you can select either m or ft Select variometer unit you can select either m s o...

Page 18: ...16 Altitude Alert High Low altitude alarm can be enabled Alert Display Set Alarm Set maximum value Set minimum value ...

Page 19: ...n accordance with a transmitter it chooses the slot 8 16 24 GPS is displayed TMA 1 can display the GPS sensor Long press the button Setting Device Sensor or GPS display item pushed for a long time this display will appear You can edit title name Select Sensor GPS is chosen Select variometer unit you can select either m s or mph Select speed unit you can select either km h or m h ...

Page 20: ... course of the model to be sure the model stays on that course Zoom in Two dimensional Long press the button Setting Device Sensor or GPS Locus display item pushed for a long time this display will appear You can edit title name Sensor is chosen Select GPS Locus In accordance with a transmitter it chooses the slot 8 16 24 ...

Page 21: ...19 Log TMA 1 can take and save sensor log data as text data 1 Start Data Logging Tap this button to start data logging Tap this button again to stop the data logging ...

Page 22: ... Log Log data is stored on the folder Internal storage TMA_1 Log of the tablet smart phone 2 Check Log Data 3 Save Log Data If a sensor is chosen Log data can see The data sorted by data Tap Log button on the initial screen ...

Page 23: ...ystem reset the TMA 1 2 Turn OFF the receiver and transmitter before switching the transmission system FASSTest or T FHSS Error message Please confirm link or restart link device Start by selecting either a tablet or smart phone 1 Note Tap the System Set button on the screen TMA 1 and a tablet smart phone are connected System Set Success Error ...

Page 24: ...uage This system supports two languages English and Japanese You can select the language English or Japanese by using the language bar in tablet or phone About Tap the About button to find the software version ...

Page 25: ...een mode alert sound and defaults can be set in this system FUTABA CORPORATION 1080 Yabutsuka Chosei mura Chosei gun Chiba ken 299 4395 Japan Phone 81 475 32 6982 Facsimile 81 475 32 6983 FUTABA CORPORATION 2014 10 1 ...