Addition of the MATRIX type of flight modes (Multicopter type only)

5 flight modes can be set to PRIORITY type. 9 flight modes can be set to MATRIX type.

◆ PRIORITY  TYPE

   e.g. Setting 5 flight modes in MultiCopter Model Type

◆ MATRIX  TYPE

   e.g. Setting up the transmitter to operate the tilt of a camera using switches A and C. 

The mode change rate of 

the multicopter control 

box (CH6 use)

[TLEMETRY]  Page 2

[Current setting screen]

[Voltage setting screen]

[Capacity setting screen]

Camera tilt 

control rate

Camera tilt 

control rate

●Vibrator ON/OFF

●Vibrator ON/OFF

●Vibrator ON/OFF

Activating 

CH6

 and 

CH7

 

allows  the  functions  to 

control the camera angle. 

CH6 sets the option to 

change modes. 

[PRIORITY]

 is select by 

3 pages.

[MATRIX]

 is select by 

3 pages.

Flight mode change 

switch

 

SWA

SWC

Flight Mode

Normal

F-Mode 1

F-Mode 2

F-Mode 3

F-Mode 4

 

SWA

SWC

CAMERA   Servo Rate

100

100

100

50

100

0

50

100

50

50

CH6

CH7

50

0

0

100

0

50

0

0

Addition of the current sensor and voltage sensor function

Compatible with the SBS-01C (current sensor) and SBS-01V (voltage sensor).

●"DN"  indicates  the 

alarm will start when 

the  current  reaches 

below your set value.

●"DN"  indicates  the 

alarm will start when 

the  voltage  reaches 

below your set value.

●"DN"  indicates  the 

alarm  will  start  when 

the capacity reaches 

below your set value.

●"UP" indicates the alarm will start 

when the current reaches above 

your set value.

●"UP" indicates the alarm will start 

when the capacity reaches above 

your set value.

●Current

●Voltage

●Consumption 

capacity

● Switch selection  

● Switch selection  

● Switch selection  

●Speech function. 

●Speech function. 

●Speech function. 

●The maximum and the minimum 

when powering ON are shown.

●The maximum and the minimum 

when powering ON are shown.

●The maximum and the minimum 

when powering ON are shown.

●  Maximum  and  minimum  date 

reset by pressing the

 Jog key 

for 1 

second.

 

●  Maximum  and  minimum  date 

reset by pressing the

 Jog key 

for 1 

second.

 

●  Maximum  and  minimum  date 

reset by pressing the

 Jog key 

for 1 

second.

 

FUTABA CORPORATION     Phone: +81 475 32 6982, Facsimile: +81 475 32 6983

1080 Yabutsuka, Chosei-mura, Chosei-gun, Chiba 299-4395, Japan

©FUTABA CORPORATION     2016, 12  (1)

The 

SBS-01C

 can monitor and display 

the in-flight current, voltage, and current 

consumption of the drive battery.

The 

SBS-01V

 can monitor and display 

the in-flight voltage of the drive battery.

*Solder welding is required for instruction.

Summary of Contents for T6K

Page 1: ...d window appears on the screen Click Locate and install driver software When the CIU 2 is first connected to the PC the Found New Hardware Wizard window appears on the screen Install the drivers downl...

Page 2: ...m our website or your local distribtor s website http www rc futaba co jp Updating procedure 2 Extract the zip file on your computer Futaba WEB site Software Download 2 S I F Port CGY750 GY701 GY520 E...

Page 3: ...tter power while pressing down the END and button 4 CIU 2 Turn on the transmitter power while pressing down the END button Press the END and button next turn ON Press the END button next turn ON CIU 3...

Page 4: ...4 Don t turn off the power 5 Start an executable file by a PC Double click Write OK PC T6K Wait for about 30 seconds 3 minutes CIU 3 CIU 3 CIU 2 CIU 2 T6K...

Page 5: ...emove the CIU 3 CIU 2 7 Check the software version at TX SETTING 8 Be sure to check the each function before use Shut down the update software Turn off the power and then turn on the power while press...

Page 6: ...ttery is unplugged during the update In the case of a failed update the transmitter may not restart In this situation try the following steps to retry the updating procedure 1 Detach the battery from...

Page 7: ...ation of the timer Once the time is reached the vibrator motor will turn on The type of vibration can be selected by the user T6K SOFTWARE UPDATE CHANGES Version 2 0 This software updates or alters th...

Page 8: ...rt when the current reaches below your set value DN indicates the alarm will start when the voltage reaches below your set value DN indicates the alarm will start when the capacity reaches below your...