FUTABA T18MZ Software Update Changes Download Page 5

1M23N26412

T18MZ SOFTWARE UPDATE CHANGES

(Editor Version: 2.1,2.2 and 2.3 Encoder version: 2.0)

This software updates or alters the functions and features noted below.  The instructions and information that follow are meant as a supplement to the original instruction 
manual that accompanied the T18MZ transmitter.  Please refer to the original instruction manual where applicable, but replace the steps indicated below with these 
instructions. Please note that the software update will be finalized the first time that the T18MZ is powered up, after the software has been applied.  As such, it may require a 
few moments before the Start screen appears.  
Please check to ensure that the update has been installed.
1) Select the System Menu.
2) Touch the [Information] button.
3) Confirm that the information in the display indicates the Editor and Encoder version numbers as noted above.

Voltage display function

 *

The change part of V2.3 is only this.

This function allows some voltage sensor units to be compatible with 
Futaba's voltage sensor unit (SBS-01V).

Setting method

Register the SBS-01V at the transmitter from the [Sensor] setting screen 

in the Linkage Menu.

The [Telemetry] screen in the Linkage Menu opens. The voltage 

information is displayed.

9ROWDJH

[Alert]: If it turns OFF (ON) from INH, it will warn at the time of voltage 

drops. 

[Threshold]: The voltage which starts warning is inputted.

[Vibration]: If Type 1-4 is used from OFF, it will warn by each vibration. 

[Speech]: INH

ACT ; a voice alarm is given in addition to the alarm 

sound when the alarm was activated.

The voice of T18MZ

 *

The change part of V2.3 is only this.

The voice of T18MZ changed from the man to a woman.

Home 2 screen telemetry display function

The Home 2 screen telemetry display function has been refined to display 
more information. In addition to the current measured value, the display 
also indicates the minimum and maximum values.

Setting method

Touch the [Home 2] button in the Home screen to open the [Home 2] 

screen.

Select the desired sensor unit, and open the details display screen.

Touch the [Select] button on the [Home 2] screen. The Home 2 setting 

screen appears.

Alternatively, the detail display screen may be accessed as follows: 

[Linkage Menu]

[Telemetry]

selected sensor

Home 2 [Select]

It is possible to display up to three types of telemetry data on the Home 

2 screen.

[Display]: The value indicated (on/off) determines whether or not the 

sensor data will be displayed in the Home 2 screen. 

[Slot]: Sets the slot number of the sensor unit to be displayed.

[Sensor type]: Displays the selected sensor type.

[Value Type]: Indicates the data to be displayed from among the 

measured data of each sensor unit.

[Timer and PIT and THR]: When set to [ON], displays the timer (when the 

model type is helicopter, pitch/throttle position) on the Home 2 screen. 
When set to [OFF] displays the telemetry data maximum and minimum 
values and the voice button on the Home 2 screen.

       ●

Home 2 screen when [OFF]

Audible telemetry information

In addition to the on-screen telemetry data information, the T18MZ now has 
the ability to audibly indicate the aircraft status.

The voice is in English.

The audible indicator is capable of noting the data from any (or all) of the 

three sensors selected.

When using the voice read function set the [Timer and PIT and THR] 

setting of the Home 2 screen to the [OFF] mode.

It is possible to adjust how often the data is conveyed to the modeler.  

The frequency ranges from 0-30 seconds.  If set at 0, updates will occur 
continuously.  If set to 30, updates will occur every 30 seconds.  

The T18MZ offers the ability to adjust the volume of the audible telemetry 

data.  The volume for the telemetry data is combined with the Error/
Warning volume.  To access this adjustment: [System Menu] -->[Sound 
Volume] -->Error/Warning.

 It is also possible to turn the audible information on/off by the use of an 

arbitrary switch and/or switch position.

When only one kind of data is set to read ON, the data is repeatedly 

read in the following order:

[Sensor Type, Data, Units] [Data] [Data] [Data] [Data]
(Example) Reading of receiver voltage
"Battery eight point one volt, eight point one, eight point one, eight point 

one, eight point one, Battery..." is repeated. If you have activated the 
audible indicators for multiple sensors, the T18MZ will cycle through the 
indicators at the selected timing intervals accordingly.

When the voice read function is turned on for telemetry data with alarm 

set when an alarm is activated; a voice alarm is given in addition to the 
alarm sound when the alarm was activated.

["Warning"] [Sensor Type, Data, Units]

Setting method

In the Linkage menu, select the telemetry screen to make adjustments to 

the sensors.  Touch the button associated with the sensor for which you 
would like to adjust.

If both the alarm (alert) and the speech (audible information) indications 

are active, and the alarm threshold is exceeded, the T18MZ will sound a 
warning accordingly.

Touch the [Select] button of [Home 2]. The Home 2 setting screen 

appears. Set [Timer and PIT and THR] to [OFF]

 Select the telemetry data that is to be read by voice.

As mentioned previously, it is possible to adjust the time, or interval, 

between the audible updates from the sensor(s).  To do so, press the 
speech Interval button then use the rate adjustment buttons to select the 
desired interval.  The interval ranges from 0 (continual updates) to 30 
(information noted every 30 seconds).  Press [Close] when done.

-

 

1 -

Summary of Contents for T18MZ

Page 1: ...ftware T FHSS is still not available for the T18MZ 6 If you copy model data whose system type is T FHSS into a T18MZ the system type of it will be converted to FASSTest automatically 1 SBS 01C current...

Page 2: ...7HOHPHWU 6HWWLQJ EXWWRQ LQ WKH LQNDJH 0HQX WR FDOO WKH VHWXS VFUHHQ VKRZQ EHORZ 7R VZLWFK VHOHFW VFUHHQ 7XUQV 21 2 WKH WHOHPHWU DODUP OO WHOHPHWU DODUPV VWRS It changed from Telemetry Log to Telemetr...

Page 3: ...1 Angle alert setting of servo 1 Connection Alarm 1 Connection alert setting of servo 1 Current 2 Current alert setting of servo 2 Temperature 2 Temperature alert setting of servo 2 Angle 2 Angle aler...

Page 4: ...emetry data begins Absolutely never remove the SD card while log data is being recorded Set the switch set by Log Start Stop Switch to OFF A beeping sound is generated and recording of the telemetry d...

Page 5: ...e displayed from among the measured data of each sensor unit Timer and PIT and THR When set to ON displays the timer when the model type is helicopter pitch throttle position on the Home 2 screen When...

Page 6: ...elemetry display units can now be set to metric system or Imperial system Setting method Open the telemetry display units setting screen by touching Unit System in the System Menu Select Metric or Yar...

Page 7: ...T18MZ This may be done manually within the transmitter s program Alternatively registration of the sensor may be accomplished through the sensor unit registration function which follows Setting method...

Page 8: ...g the Sensor button in the Linkage Menu Touch the 1 2 to enter the second page of the setting screen Then touch the Relocate button If reallocation was successful a screen like the following will appe...

Reviews: