4-4-3 Setting alarm monitoring conditions
Perform alarm setting as needed. If alarm setting is not required or only measurement is performed, save the
settings after setting the measurement conditions and the sensitivity of the sensors. After the settings are saved,
the operation screen is restored.
* For saving the settings, refer to Sections 4-5,
“Saving Settings As,” and 4-6, “Saving Settings”. (→Page 27)
When performing alarm setting following the setting of sensor sensitivity, click the inside of the dotted frame in
the following figure.
The figure at left shows an example of alarm setting for
channel 1.
The setting window appears. The following figure shows the window displaying Template waveforms.
* Reading the Template waveforms in advance in the frame window displays the Template waveforms also in
the alarm setting window and makes it easy to set alarm conditions.
* For reading the Template waveforms, refer to Section 6-1,
“Displaying Template Waveforms”. (
→
Page 30)
Six alarm monitoring items are provided.
Set these items by directly entering numerical values or using the monitoring range edit tool on the toolbar.
Multiple monitoring items can be set for one sensor.
Do it as needed.
(Refer to the following page for details of the procedure for setting monitoring items.)
①
Monitoring zone 1
Monitors the maximum pressure value in the set range of the monitoring time
whether it is within the pressure range set. (Judgment: Peak)
Monitors all measurement values in the set range of the monitoring time whether
they are within the pressure range set. (Judgment: Area)
②
Monitoring zone 2
Same as above
③
Point monitoring (Monitor after t
seconds)
Monitors the pressure values in the elapsed time set whether they are within the
pressure range set.
④
Time-to-peak monitoring
Monitors the maximum pressure value (peak pressure value) in the measurement
time whether it is within the set range of the monitoring time.
⑤
Integral monitoring
Monitors the entire waveform area (an area surrounded by pressure waveforms and
time axis) whether it is within the set range of integral values.
⑥
Integral to peak monitoring
Monitors the integral value up to the maximum pressure value (peak pressure
value) in the measurement time whether it is within the set range of integral values.
①
②
③
④
⑥
⑤
Alarm conditions can
be easily set using
the monitoring range
edit tools.
The specified
monitoring conditions
are applied to all
channels.
⑦