The GY701 is used by connecting the “rpm” input
to the governor speed setting channel of your sys-
tem. When using an independent governor on/off
switch, activate the “(6) Governor on/off switch”
funtion within the “
Governor Basic Setting
” section
earlier in this manual. (S.BUS connection only)
Direct set by transmitter on Gov. mixing
When governor mixing as in the T14MZ and
T12FG is used to switch the RPM of the rotor
head speed. The head speed can be switched
with each condition or the switch.
*For a description of the governor mixing, refer to
your transmitter’s manual.
Using by 3position switch
Set the RPM at each switch position in the “(2)
Revolution setting” menu within the “
Gov-
ernor Basic Setting
” section earlier in this
manual.
Speed setting precautions
s7HENTHESPEEDSETTINGCHANNELTRAVEL%0!!46
!&2 ISSETTOORLESSPOINTSANDCANNOT
be set.
s4HE ENGINE MAXIMUM SPEED RANGE LIMITS THE
maximum speed setting.
s4EST FLY THE HELICOPTER WITH THE GOVERNOR TURNED
OFFANDTACHTHEMAINROTOR20-WHILEINHORI
-
ZONALmIGHT4HISISTHEMAXIMUM20-THATCAN
be achieved with the engine and pitch setup that
you are using. Please set the governor maximum
SPEEDTOAPPROXIMATELY20-SLESSTHANMAX
20-%XAMPLE)F20-SISMAXTHENSET
Summary of Contents for GY701