13
2.5. Construction Material List
Local contractor/client supply
Cables & Tube
Junction Unit --- Data Processing Unit
Items
Descriptions
Length
Qty
LAN cable
1000Base-T (
Must use STP (Shielded Twisted Pair) instead of
UTP (Unshielded Twisted Pair).
Length depends on measure
value. Incl. RJ45 LAN connector w/ cover. Refer to Appendix B
for more detail.
by measure
2
AC power cable
for JCU
VCTF 2sq 3core or equivalent (Recommendation is with
shielded). Also with crimped terminal (2sq φ4.3) for JCU
and local plug (Figure 2.2)
by measure
1
Type of power
plug
Please prepare a country specific power cord of IEC60320
C13 to local plug if local outlet is using different type as
below.
- DPU PS attached Type-B plug
- LCD monitor attached Type-B w/ GND strap
By measure
2
Protective tube
PV tube or pipe conduit (Water/Dust proof).
Inner diameter: φ28mm (Outer diameter: φ36.5mm)
by measure
1
Tube connector
φ28 (Water/Dust proof) when using a wall mount pull box
(Inner 28mm, Outer 36.5mm JIS standard)
-
1
Basic expendable supplies
Items
Descriptions
Qty
Heavy Duty Cable Tie (2 types)
Nylon 6/6 w/ weather resistance 100mm, 150mm
Multi
Basic construction tools
Items
Descriptions
Hex key (Ball-head type)
M4 (3mm)
Ratcheting Wrench
M5 (8mm), M12 (19mm), M16 (24mm),
Adjustable wrenches (up to 30mm)
Socket Wrench
M10 (17mm) for fixing radome upper/bottom
Exclusive Philips head screwdriver #1
Multiuse
Philips head screwdriver #2
Multiuse
Slotted head screwdriver 3mm
Multiuse
Cable/Wire cutting scissors
Multiuse
Flat nippers
Multiuse
Wire Strippers
For electric wiring work
Ratchet Wire Crimper 2sq
For electric wiring work
LAN cable strippers
For LAN cable work
LAN Ratchet Crimper
For LAN cable work
LAN cable tester
For LAN cable work
Crimp terminal
V2-M4 2sq, Outer ring 6.6mm, Inner ring 4.3mm
Refer to section 3.2 for size detail
Note:
Ask FEC if anything above can hardly purchase at local area.
Figure 2.2: Shielded power cable fixed to AC plug
The other side goes to JCU
also need to crimp ring
terminals.
Joint shield GND with GND cable
Local plug
Summary of Contents for WR110
Page 1: ...INSTALLATION MANUAL WEATHER RADAR MODEL WR110 www furuno com...
Page 49: ...43 6 OUTLINE DRAWING 1 Antenna Unit...
Page 50: ...44 2 Junction Unit connection box...
Page 51: ...45 3 Junction Unit Wall mounted type...
Page 52: ...46 4 Data Processing Unit...