![Furuno RC-1800T Installation Manual Download Page 19](http://html1.mh-extra.com/html/furuno/rc-1800t/rc-1800t_installation-manual_2350553019.webp)
2. WIRING
2-3
2.4
Connection of External Equipment
Pass the cables of external equipment through the cable entrance at the bottom of the
console. Connect the cable to terminal blocks TB1 to TB4, referring to this section and
the interconnection diagram.
Connect the cables of external equipment to the terminal blocks (TB1 to TB4) through
the cable entrance at the bottom of the console.
2.4.1
Terminal block TB1
2.4.2
Terminal block TB2
Terminal
no.
Destination
Signal line
1 to 2
PR-850A
Back-up DC LINE IN (#1: (+), #2: (-))
3 to 4
DC LINE OUT (#3: (+), #4: (-))
5 to 6
AC FAIL (#5: (+), #6: (-))
7 to 8
PR-300
Back-up DC LINE IN (#7: (+), #8: (-)
9 to 10
No.1 VHF
DC LINE OUT (w/Back-up) (#9: (+), #10: (-))
11 to 12
No.2 VHF
DC LINE OUT (w/Back-up) (#11: (+), #12: (-))
13 to 15
Fuse Box
16 to 17
—
NC
18
Charger
Unit
CHARGE
19 to 20
BATT OUT (#19: (+), #20: (-))
21
24 VDC
22
0 VDC
1
2
7
8
3
4
9
10 11 12
5
6
13 14 15 16 17 18 19 20 21 22 23
PR-850A
PR-300
#1 to #6
VHF
#9 to #12
#7 to #8
Fuse Box
#13 to #15
Battery Charger
#18 to #22
LED flexible light
#1 to #4
VHF
#18 to #21
BAM
#23 to #31
#15, #16
FAX
GPS
#5 to #13
7
8
5
6
3
4
1
2
15
16
13
14
11
12
9
10
23
24
21
22
19
20
17
18
29
30
31
32
27
28
25
26
Insert cores (Either entrance is available).
Summary of Contents for RC-1800T
Page 6: ...EQUIPMENT LISTS iv This page is intentionally left blank...
Page 26: ...2 WIRING 2 10 This page is intentionally left blank...
Page 28: ...3 CHECKING OPERATION 3 2 This page is intentionally left blank...
Page 32: ...D 1 13 Apr 2015 H M AKI 13 Apr 2015 H MAKI...
Page 33: ...D 2 13 Apr 2015 H M AKI 13 Apr 2015 H MAKI...
Page 34: ...D 3...