background image

SYSTEM CONFIGURATION

vi

NMEA 2000 network

NOTICE:

 Turn on the terminal resistor in the terminator of the NMEA 

2000 network.

FI-501*
and/or
FI-502

FI-5001

WIND

TRANSDUCER

TERMINAL BOX

(where necessary)

FI-503

DIGITAL

FI-504
MULTI

FI-505

COURSE PILOT

FI-506

RUDDER

30

: Standard Supply
: Optional Supply
: Local Supply

*FI-501 Wind Angle
 FI-502 Close Hauled Wind Angle

JUNCTION BOX

FI-5002

* NMEA 2000 SENSORS
   - Boat speed
   - Depth
   - Heading
   - Navigation
   - Environment
   - Autopilot
   - Engine

12 VDC
(not necessary if powered
by NMEA 2000 network)

NMEA 2000
SENSOR*

NMEA 2000
SENSOR*

NMEA 2000
SENSOR*

NMEA 2000
SENSOR*

NMEA 2000
SENSOR*

Summary of Contents for Multi Instrument FI-504

Page 1: ...www furuno co jp FI 504 MULTI Instrument...

Page 2: ...istributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN Telephone 81 0 798 65 2111 Fax 81 0 798 65 4200 A OCT 2007 Printed in Japan All rights reserved A1 OCT 17 2007 Pub No OME 72690 A1 000167...

Page 3: ...shown in this manual may not match the screens you see on your display The screen you see depends on your system configuration and equipment settings Store this manual in a convenient place for future...

Page 4: ...he operator Make sure no rain or water splash leaks into the equipment Fire or electrical shock can result if water leaks into the equipment Immediately turn off the power at the switchboard if water...

Page 5: ...a Display 3 1 5 Selecting Apparent or True Wind Angle Wind Speed 8 1 6 Resetting Counters and Indications 8 1 7 Alarms 9 1 8 Timers 11 2 MAINTENANCE TROUBLESHOOTING 13 2 1 Preventive Maintenance 13 2...

Page 6: ...mmended procedures for operation and maintenance Thank you for considering and purchasing FURUNO equipment Features The FI 504 Multi Display provides heading environment autopilot en gine depth speed...

Page 7: ...TICE Turn on the terminal resistor in the instrument when connecting an NMEA 2000 sensor For the procedure see the section on setting up in the installation chapter Standard Supply Optional Supply Loc...

Page 8: ...503 DIGITAL FI 504 MULTI FI 505 COURSE PILOT FI 506 RUDDER 30 Standard Supply Optional Supply Local Supply FI 501 Wind Angle FI 502 Close Hauled Wind Angle JUNCTION BOX FI 5002 NMEA 2000 SENSORS Boat...

Page 9: ...data Autopilot rudder Engine Wind Timers Navigation data 1 1 Operating Controls Display Layout SELECT CLEAR Select menu option Silence alarm Clear data Reset counters and indcations Increment value A...

Page 10: ...Within seven seconds of completing step 1 press the APP TRUE key to lower the brilliance or the SELECT CLEAR key to raise it 3 Press the DISP and MODE keys together The display for adjustment of contr...

Page 11: ...ip fuel usage Fuel usage rate Engine RPM SPEED Boat speed Maximum STW Average STW SOG Maximum SOG Average SOG VMG to windward Log Trip TIMER Count up timer Count down timer 1 Count down timer 2 DEPTH...

Page 12: ...Indication Function Boat speed SPD Boat speed in knots kt miles per hour MPH or kilometers per hour KMH Maximum STW SPD MAX Maximum boat speed in knots kt miles per hour MPH or kilometers per hour KMH...

Page 13: ...PP or TRUE Apparent or true wind angle in degrees High apparent wind angle alarm APP HI Set high apparent wind angle alarm Audio and visual alarms are released when the wind angle at starboard goes hi...

Page 14: ...sm Display title Indication Function Bearing to waypoint BTW Bearing to waypoint in degrees Bearing reference of Magnetic MAG or True TRUE Distance to waypoint DTW Distance to waypoint in kilometers K...

Page 15: ...in Hectopascal Humidity HUMID Relative humidity in percentage Wind chill temperature CHILL Wind chill temperature in C or F Dew point DEW Dew point in C or F Display title Indication Function Rudder a...

Page 16: ...Wind angle and wind speed displays are mutually changed True wind requires boat speed input If there is no speed input three dashes appear 1 6 Resetting Counters and Indications You can reset the foll...

Page 17: ...than this threshold Deep anchor alarm anchor depth is greater than this threshold depth is deeper than this threshold Max true wind speed alarm max true wind speed is greater than this threshold 0 1 9...

Page 18: ...5 Press the APP TRUE and SELECT CLEAR keys together to confirm setting and restore normal operation When an alarm is violated the buzzer sounds and the alarm icon flashes You can silence the buzzer w...

Page 19: ...in time Two beeps every minute Three beeps at the start of the last 30 seconds One beep second for each of the last 10 seconds Two second beep at zero How to set the timers 1 Press the MODE key to sho...

Page 20: ...ds when the timer is stopped or restarted To stop and reset the timer to start value press the SELECT CLEAR key until you hear a long beep The timer is stopped and reset to start value The timer setti...

Page 21: ...ll cabling is securely fastened and is free or rust and corrosion Reconnect if necessary Replace if damaged Cabinet Dust on cabinet Remove dust with a soft lint free cloth WARNING Do not open the equi...

Page 22: ...d or damaged Check power supply Check cabling Power is on but no or some data Sensor is turned off Cable from sensor is disconnected or damaged Turn on sensor Check cabling Inaccurate data Electromagn...

Page 23: ...45 10 1 FI 50 CHAIN 0 3M 000 166 949 10 1 FI 50 CHAIN 5M 000 166 951 10 1 FI 50 CHAIN 1M 000 166 950 10 1 FI 50 CHAIN 10M 000 166 952 10 1 FI 50 CHAIN 20M 000 166 953 10 1 Flush Mount Kit FI 50 FLUSH...

Page 24: ...ely Surface mount 1 Fix instrument from front panel 1 Using the template at the back of this manual open a mounting hole in the installation site 2 Detach the front panel together with the keypad assy...

Page 25: ...a mounting hole in the installation site 2 Insert studs M3 40 2 pcs supplied in the holes shown below Use only the studs supplied 3 Set the display unit to the mounting hole inserting studs through r...

Page 26: ...m standard supply Red Black DISP UNIT FI 504 DISP UNIT FI 501 502 FI 503 FI 505 FI 506 Instruments can be connected in any order FI 50 CHAIN 0 3 m Std 1 5 10 20 m Option FI 5002 POWER CABLE 2 m NMEA 2...

Page 27: ...ks Detach plug to connect wiring to it by rocking it back and forth with your fingers Remove approx 6 mm of the sheath from the end of wires and twist wires Loosen fixing screw in the plug insert wire...

Page 28: ...FI 5002 FI 50x FI 5002 FI 50x FI 50x Multiple FI 50 series instruments FI 5002 smart sensor Smart Sensor Multiple FI 50 series instruments multiple FI 5002 FI 5002 FI 50x FI 50x FI 5002 FI 50x FI 50x...

Page 29: ...after completion of the installation Two sets of setup menus are provided setup1 and setup2 The setup1 menu provides system parameters and the setup2 menu has user set tings 3 4 1 Setup1 menu The set...

Page 30: ...unit SPD KT CAL Speed unit resolution SPD CAL 0 01 Speed offset SPD 1 0 Speed response SPD RES CAL 3 VMG response VMG RES CAL 0 Audio alarm enable disable TIMER CAL On Wind data selection WIND CAL F...

Page 31: ...er the setting the faster the response to change in depth 0 12 3 Select speed unit KT Knot MPH Miles Hour KMH Kilometers Hour KT Select speed resolution Select number of places to show after decimal p...

Page 32: ...arm s audio alarm ON OFF ON Select source of wind data Select r for second unit F For FI 5001 r repeater F Select wind unit KT Knot M S Meters Second KT Set wind speed adjustment 0 3 2 5 1 0 Set wind...

Page 33: ...ange in heading 0 12 0 Select time format 12 24 hour 12 Use local time Enter time differ ence between local time and GMT to use local time 12 12 0 Select water temperature unit C F C Set water tempera...

Page 34: ...select another item 5 To save settings and restore normal operation press the APP TRUE and SELECT CLEAR keys together XXxxx Program ver no CPU2 XXxxx Program ver no CPU1 KEYBEEP CAL Key beep ON Auto b...

Page 35: ...oat spd water temp 5 Roll pitch 6 Latitude Longitude OFF Enable disable access to the setup1 menu ON OFF ON Turn the terminal resistor on off ON OFF OFF Turn on off synchronization of FI 50 series ins...

Page 36: ...o mode To enable press the SELECT CLEAR key Depth is shown To disable and return to this menu press and hold down the SELECT CLEAR key ON OFF OFF Restore factory defaults To restore factory defaults p...

Page 37: ...NMEA 2000 Backbone 2 ports 3 POWER SUPPLY AND POWER CONSUMPTION 3 1 Display Unit 12 VDC less than 0 1 A 3 2 Junction Box 12 VDC less than 1 A max 2A connectable 4 ENVIRONMENTAL CONDITIONS 4 1 Useable...

Page 38: ...453 10 WING NUT 2 M3 SUS304 000 167 826 10 BOLT 2 M3X40 SUS304 000 167 804 10 CABLE ASSY 1 FI 50 DROP 000 166 945 10 0 3M CABLE ASSY 1 FI 50 CHAIN 0 3M 000 166 949 10 DOCUMENT INTERNAL RESISTOR SETTIN...

Page 39: ...ER TZ7580007AO 1 000 167 887 10 3 CODE NO FRAME TZ7580008AO 1 000 167 886 10 4 CODE NO 1 SELF TAPPING SCREW 3X20 SUS304 4 000 163 884 10 5 CODE NO P SCREW 3X12 SUS304 4 000 167 827 10 6 CODE NO F SPON...

Page 40: ...Jul 24 07 R Esumi D 1...

Page 41: ...Jul 24 07 R Esumi D 2...

Page 42: ...Jul 24 07 R Esumi D 3...

Page 43: ...m 1 FI 50 CHAIN 0 3m 6 SHIELD NET S NET C NET H NET L 1 2 3 4 5 NMEA2K INSTRUMENT SHIELD NET S NET C NET H NET L 1 2 3 4 5 NMEA2K FI 503 504 505 506 SR7000 LTW12 05AFFM SR7000 LTW12 05AMMM 1 5 10 20m...

Page 44: ...4 For tapping screws 4 pcs 2 For bolts 2 pcs...

Page 45: ...FI 50 FI 50 series Display unit Flush Mount Template...

Reviews: