background image

 

2

Cables 

Use the following cables (Japan Industrial 
Standard cables) or the equivalents. 

Conductor

S = 0.75 mm

φ

 = 1.11 mm

2

TTYCS-1 (Twisted pair cable)

Conductor

S = 0.75 mm

φ

 = 1.11 mm

2

TTYCS-1Q (Four core twisted)

Conductor

S = 1.5 mm

φ

 = 1.56 mm

2

DPYC-1.5

Armor

Armor

Armor

Sheath

Shield

Shield

Sheath

Sheath

Current loop or RS-422

Power cable

AD-10 format

φ 

11.7 mm

φ 

10.1 mm

φ 

11.3 mm

 

 

We recommend use of the following crimp-on 
lug. 

φ

 = 6.6 mm

φ

 = 3.7 mm

FV1.25-M3 (Code no.: 000-538-110)

4.0 mm

 

Mounting 

This unit has not power switch. If you do not 
connect the MD-550 to power switchboard or 
circuit breaker, install an external power switch 
(local supply), locating it near the MD-550. 

14

5

216

Jumpers

LEDs

CR4 (POWER)
CR5 (IN1)
CR6 (IN2)

Jumpers

 

POWER LED: Lights when the power is 

supplied. 

IN1 LED: Blinks when data is input. 
IN2 LED: Blinks when data is input. 
 
Note:   You can confirm working of output port 

(by LED) by connecting it to the other 
input port. (Refer to schematic diagram.) 

Input1

Input2

Output1
Output2
Output3
Output4

Output5
Output6
Output7
Output8

CR5

CR6

 

Connection for confirming working of output 

port 

 

Summary of Contents for MD-550

Page 1: ...MULTI DISTRIBUTOR MD 550...

Page 2: ...J a p a n Te l e p h o n e 0 7 9 8 6 5 2 1 1 1 Te l e f a x 0 7 9 8 6 5 4 2 0 0 Yo u r L o c a l A g e n t D e a l e r A l l r i g h t s r e s e r v e d P U B N o O M E 4 4 0 8 0 M D 5 5 0 T E N I F I...

Page 3: ...be minimal The location should be free of water spray Do not install this unit on the overhead Do not use the cable having a diameter greater than 11 7 mm CAUTION CAUTION Observe the following compass...

Page 4: ...TS System Configuration 1 Installation materials and Spare parts 1 Cables 2 Mounting 2 Setting 3 Fabrication of signal cable 3 SPECIFICATIONS SP 1 PACKING LIST OUTLINE DRAWING INTERCONNECTION DIAGRAM...

Page 5: ...tput7 Output8 Input1 Output1 Output2 Output3 Output4 12 24 VDC When connecting by current loop the standard FURUNO receive circuit current limiter circuit 470 photocoupler PC 400 900 are included acce...

Page 6: ...Code no 000 538 110 4 0 mm Mounting This unit has not power switch If you do not connect the MD 550 to power switchboard or circuit breaker install an external power switch local supply locating it ne...

Page 7: ...mper into connector in same direction as before Note2 Do not short jumpers JP13 JP14 They should be open Fabrication of signal cable DPYC 1 5 77 3 6 Armor Cut the sheath Vinyl tape Sheath 15 10 1 Crim...

Page 8: ...by changing an internal setting AD 10 format signal is also available to distribute four outputs from one input 1 Port Input 2 ports data shift lines Output 8 ports 4 output for one input 2 Type of S...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: