How to attach N-P-8DFB connector (for extension cable kit)
Outer Sheath
Armor
Dimensions in millimeters.
Inner Sheath Shield
Remove outer sheath and armor by the dimensions
shown left.
Expose inner sheath and shield by the dimensions
shown left.
Cut off insulator and core by 10 mm.
Twist shield end.
Slip on clamping nut, flat washer, gasket and clamp
as shown left.
Fold back shield over clamp and trim.
Cut aluminum foil at four places, 90
°
from one
another.
Fold back aluminum foil onto shield and trim.
Remove insulator up to edge of washer 2.
Expose the core by 5 mm.
Slip the pin onto the conductor. Solder them together
through the hole on the pin.
Insert the spacer and housing. Screw the clamping
nut into the housing.
(Tighten by turning the clamping nut. Do not tighten
by turning the housing.)
Cover with heat-shrink tubing and heat.
30
10
Clamping
Nut
Gasket
(reddish
brown)
Clamp
Aluminum Foil
Trim shield here.
Trim aluminum
tape foil here.
Insulator
5
Clamping Nut
Pin
Housing
Solder through
the hole.
50
30
Washer 2
Flat Washer
Spacer
How to attach N-P-8DFB connector
8