4
3.
Interconnection and Settings
3.1.
Interconnection
Notes:
(1)
When the SCX-21 is connected to the GP-
39, the original antenna GPA-017 or
GPA-C01 CANNOT be used.
(2)
In the configuration of an SCX-21 with a GP-39, the GP-39 NMEA0183 output port is occupied
by the SCX-21. In order to output/input data from/to the SCX-21, utilize Data 2 and
Data 3 ports of SCX-21. (Data 2 is output only)
3.2.
Setting – Operation Mode
Change the operation mode of the GP39 to make the GP-39 work as an SCX-21 display.
Option 1 – When turning the power on for the
first time…
When the SCX-21 is turned on for the first time,
the Installation menu will launch: Access
[Operation Mode] and select [SCX-21].
(Default: [GP-39]) After changing the mode,
the GP-39 will restart.
Make sure to connect the GP-39 to the SCX-21 – Data 1 port.