![Furuno FELCOM 16 Operator'S Manual Download Page 35](http://html1.mh-extra.com/html/furuno/felcom-16/felcom-16_operators-manual_2349568035.webp)
2-1
2. SYSTEM
INITIALIZATION
This chapter provides the information necessary for initializing the FELCOM 16.
Once the equipment is initialized, you need do no more than press a few keys to
transmit and receive.
Inmarsat assigns an MES an Inmarsat Mobile Number (IMN) when it applies for
Inmarsat registration and it is entered during the installation of the MES. The
IMN is necessary to communicate in the Inmarsat system.
2.1 System
Settings
The System Setup menu provides for input of date, time, operating mode, and
port function.
1. Press the [F8] key to choose the Setup menu.
Setup
File Edit Transmit EGC Reports Logs Options
Setup
Position StopAlarm
1. System Setup
2. Editor Setup
3. Terminal Setup
4. EGC Setup
5. Auto Mode Setup
6. E-Mail Setup
7. Directories
8. Configuration
Setup menu
2. Press the [1] key to display the System Setup menu.
Setup
9. Configuration
System Setup
01:53 02-02-25 (YY-MM-DD)
INMARSAT-C
INT
INT
INT
INT
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
Network Setup
Command Window
Entered at installation
(Cannot be changed.)
Not used.
System setup menu
Note:
The IMN number is entered during the installation. The number cannot
be changed.
Summary of Contents for FELCOM 16
Page 1: ...INMARSAT MINI C MOBILE EARTH STATION FELCOM 16 OPERATOR S MANUAL www furuno co jp MODEL ...
Page 18: ...INMARSAT C SYSTEM xvi This page is intentionally left blank ...
Page 34: ...1 OPERATIONAL OVERVIEW 1 14 This page intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 130: ...4 INMARSAT C OPERATIONS 4 36 This page intentionally left blank ...
Page 144: ...5 DATA REPORTING AND POLLING 5 14 This page intentionally left blank ...
Page 167: ...APPENDIX AP 7 ...