2. INITIAL SETUP
12
1) Select a range between 0.125 and 0.25 NM and set the mode to “head up“.
You can select a range by a pinch action. The range and range ring interval
appear at the bottom left of the screen.
For TZTBB, you can also control the range in the operation as follows. Tap
the radar scale box at the bottom left-hand corner of the screen to display the
slider bar. Drag the circle icon to set the range scale.
2) Turn the vessel’s bow toward a target.
3) Press
the
Home
key (or tap the
Home
icon), then select [Menu] icon, [Radar],
and [Antenna Heading Align] in that order to show the numeric software key-
board.
4) Key in the offset value so that the target is at the very top of the screen (setting
range: +/- 0° to 180°, +: clockwise direction, -: counterclockwise direction),
then tap [Save].
5) Confirm that the target echo is displayed at correct bearing on the screen.
4
Range
Range ring interval
Range indications
Zoom out
Zoom in
Pinch action
1
Tap the area circled in the dashed line to
display the slider bar.
Note
: You can switch between transmit and
stand-by by tapping the right side of the
radar scale box.
Drag the circle
icon to set the
range scale.
Slider bar
Zoom in
Zoom out
4NM
Current
range