FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300
Fax: +1 360-834-9400
FURUNO ELECTRIC CO., LTD.
Nishinomiya, Hyogo, Japan
Phone: +81 (0)798 65-2111
Fax: +81 (0)798 65-4200, 66-4622
FURUNO (UK) LIMITED
Havant, Hampshire, U.K.
Phone: +44 23 9244 1000
Fax: +44 23 9248 4316
FURUNO FRANCE S.A.
Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00
Fax: +33 5 56 13 48 01
FURUNO ESPAÑA S.A.
Madrid, Spain
Phone: +34 91-725-90-88
Fax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00
Fax: +45 36 77 45 01
FURUNO NORGE A/S
Ålesund, Norway
Phone: +47 70 102950
Fax: +47 70 102951
FURUNO SVERIGE AB
Västra Frölunda, Sweden
Phone: +46 31-7098940
Fax: +46 31-497093
FURUNO FINLAND OY
Espoo, Finland
Phone: +358 9 4355 670
Fax: +358 9 4355 6710
FURUNO POLSKA Sp. Z o.o.
Gdynia, Poland
Phone: +48 58 669 02 20
Fax: +48 58 669 02 21
FURUNO DEUTSCHLAND GmbH
Rellingen, Germany
Phone: +49 4101 838 0
Fax: +49 4101 838 111
LLC “FURUNO EURUS”
St. Petersburg, Russian Federation
Phone: +7 812 767 15 92
Fax: +7 812 766 55 52
TRADEMARK REGISTERED MARCA REGISTRADA
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
08073KS Printed in Japan
Catalogue No. M-1531a
Display
10.4" TFT color LCD, 640 x 480 pixels
Measurements
Current
Speed:
0 to 9.9 kt
Direction: 0
to
360°
Number of layers: 3 layers
Ship
Speed:
-10 to 30 kt (fore-aft)
-9.9 to +9.9 kt (port-starboard)
Direction: 0
to
360°
Depth Range
For current measurement
2 to 75% of water depth up to 100 m
(Over 10 m of water depth is required in Ground tracking
mode. Over 40 m water depth is required in Water Tracking
mode.)
For ground tracking
3 to 200 m
Accuracy
Current:
± 2% of ship's speed + 0.2 kt
Ship's speed:
± 1% + 0.1 kt
Number of Beams
Three beams
Tilt
60° each
System Frequency
288 kHz
Data Interface
(NMEA 0183 Ver.1.5/2.0/3.0, IEC 61162)
Inputs:
DBT, DPT (Depth), GGA, GLL, RMA, RMC (L/L),
HDG, HDM, HDT (Compass), MTW (Water temperature),
VTG (SOG, COG), ZDA (UTC)
Outputs:
CUR (Water current layer), VBW (Dual Ground/Water Speed),
VDR (Set and Drift), VHW (Water speed and heading), VLW
(Distance travelled through the water), VTG (SOG, COG)
ENVIRONMENTAL
(IEC 60945 test method)
Temperature
Display Unit:
-15° to +55°
Control Unit:
-15° to +55°
Transceiver Unit: -15° to +55°
Waterproofing
Display Unit:
IPX0 (IEC 60529)
Control Unit:
IPX2 (IEC 60529)
Transceiver Unit: IPX0 (IEC 60529)
POWER SUPPLY
24 VDC, 110 W (TX)
EQUIPMENT LIST
Standard
1. Display Unit MU-100C
2. Control Unit CI-6888
1 unit
3. Transceiver Unit CI-8810
1 unit
4. Transducer CI-8840-1 with 10 m cable
1 unit
5. Thru-hull Pipe for steel hull TFB-5000CI
1 pc
6. Installation materials and spare parts
1 set
Optional
1. Junction
Box
CI-630
2. Transducer CI-8840-2 with 20 m cable
3. Transducer
Tank
CI-820/821/822/823
4. Cable for Transceiver - Junction box
Z-6FVNV-SX-C, 5/10/15/20/30 m
5. Cable for Display - Control Unit
66S1239-0, 5/10 m
SPECIFICATIONS OF CI-88
Display Unit and Control Unit
6.0 kg, 13.2 lb
Transceiver Unit
Transducer
12.0 kg, 26.5 lb
140 5.5"
160 6.3"
43 1.7"
100 3.9"
200 7.9"
(180 7.1")
4- 6.5
MU-100C and CI-6888
CI-630
CI-8810
CI-8840-1
with 10 m cable 6.1 kg, 13.4 lb
CI-8840-2
with 20 m cable 8.9 kg, 19.6 lb
357 14.1"
171 6.7"
11
°
327 12.9"
290 11.4"
300 11.8"
210 8.3"
90 3.5"
320 12.6"
320 12.6"
334 13.2"
153 6.0" 153 6.0"
6- 7
127 5.0"
41
1.6"
280 11.0''
590 23.2''
530 20.9''
566 22.3''
12
0.5''
4- 12
336 13.2''
13. 2
R10
210 8.2"
197 7.8"
20 0.8"
20
0.8"
6 0.2"
35
1.4"
88.5
3.5"
98.5 3.9"
86.5 3.4"
6.5
0.3"
10
R5
R6
6.0 kg, 13.2 lb
Flush Mount Type
Junction Box
2.0 kg, 4.4 lb