1. MAIN ALARM PANEL
1-9
1.9
Help Area
The help area displays alerts related to system failures, operational events, operation
help, etc.
1.9.1
System failure indications
This section describes how system failures are given and the accompanying operation
flow.
1. The help area shows system failure messages in white (warning level alerts have
a flashing yellow background, alarm level alerts have a red flashing background),
along with the respective alert number and icon. The alert number differs depend-
ing on the Alarm Mode chosen at installation. To change the Alarm Mode settings,
consult a FURUNO technician. Only the alert with the highest priority is displayed
in the help area. All other alerts are listed on the [Active Alert] list and [Alert Log]
screens. (See paragraph 1.9.2.)
2. The buzzer at the Main Alarm Panel sounds.
3. Press any key on the Main Alarm Panel to stop the buzzer and acknowledge the
alarm.
4. For any system error, contact a FURUNO sales representative or service techni-
cian for advice.
The tables below show the alert messages, along with their respective alert icon and
alert number, in order of priority.
Legacy Mode
AlertI/F1 Mode and AlertI/F2 Mode
Alert no. & Indication
Problem
Measures
010 Failure: Communication Communication failure between
Processor Unit and Main Alarm
Panel
Consult a FURUNO technician.
011 Failure: AC
AC power to the unit is interrupted
or stopped.
Check power to the unit, check
cabling and connections to the
unit.
012 Failure: DC
DC power to the unit is interrupted
or stopped.
Check power to the unit, check
cabling and connections to the
unit.
Alert No. & Indication
Problem
Measures
250 COM ERR with
Processor Unit
Communication failure between
Processor Unit and Main Alarm
Panel
Consult a FURUNO technician.
(220*
1
)001 DC Power
Failure
DC power to the unit is interrupted
or stopped.
Check power to the unit, check
cabling and connections to the
unit.
(220*
1
)002 AC Power
Failure
AC power to the unit is interrupted or
stopped.
Check power to the unit, check
cabling and connections to the
unit.
220003 BNWAS Alarm is
1st Stage *
2
Watch alarm is at first stage
Press any key on the Main
Alarm Panel, or press the
Timer Reset Panel button.
Summary of Contents for BR-500
Page 1: ...BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM BNWAS BR 500 OPERATOR S MANUAL www furuno com Model ...
Page 24: ...1 MAIN ALARM PANEL 1 14 This page is intentionally left blank ...
Page 72: ...D 1 6 Oct 2011 Y NISHIYAMA ...
Page 73: ...D 2 6 Oct 2011 Y NISHIYAMA ...
Page 74: ...D 3 9 Feb 2011 Y NISHIYAMA ...
Page 75: ...D 4 6 Oct 2011 Y NISHIYAMA ...
Page 76: ...D 5 16 Feb 2011 Y NISHIYAMA ...
Page 77: ...D 6 16 Feb 2011 Y NISHIYAMA ...
Page 78: ...D 7 20 Jun 2012 Y NISHIYAMA ...
Page 79: ...D 8 9 Mar 2011 Y NISHIYAMA ...
Page 80: ...D 9 6 Oct 2011 Y NISHIYAMA ...
Page 81: ...D 10 16 Feb 2011 Y NISHIYAMA ...
Page 82: ...D 11 16 Feb 2011 Y NISHIYAMA ...
Page 83: ...D 12 20 Jun 2012 Y NISHIYAMA ...
Page 84: ...D 13 6 Oct 2011 Y NISHIYAMA ...
Page 85: ...D 14 16 Feb 2011 Y NISHIYAMA ...
Page 86: ...D 15 16 Feb 2011 Y NISHIYAMA ...
Page 87: ...D 16 20 Jun 2012 Y NISHIYAMA ...
Page 88: ...D 17 16 Feb 2011 Y NISHIYAMA ...
Page 89: ...D 18 16 Feb 2011 Y NISHIYAMA ...
Page 90: ...D 19 20 Jun 2012 Y NISHIYAMA ...
Page 93: ......