2. Display Modes
1. Full circle searchlight
2. Zoom (x 1.5)
3. Vertical-fan scanning
4. Vertical sounding
5. Full circle search and Vertical scan
6. Full circle search with Historical display
7. Semi circle search and Strata display
8. Full circle search and Video Plotter
3. Color
8 or 16 colors, plus white
4. Audio monitor
1000 Hz
5. TX Output Power
0.8-1.2 kW
6. Beamwidth
(at -3 dB)
60 kHz
15˚ (H) x 12˚ (V)
88 kHz
11.5˚ (H) x 9.5˚ (V)
150 kHz
6.5˚ (H) x 6.5˚ (V)
7. Transducer Control
Tilt
0˚ to -180˚ at 3˚ or 6˚ steps (in vertical scan)
+5˚ to -90˚ at 1˚ steps (in full circle scan)
Training sector
Manual or automatic training at 6˚ or 12˚ steps
in search sector of 6˚-360˚
Target Lock
By L/Lor Echo position
8. Interface
NMEA0183 Ver. 1.5, 2.0 (IEC 61162-1)
Input:
DBS, DBT, DPT, GGA, GLL, HDG, HDM, MDA,
MTW, RMA, RMC, VDR, VHW, VTG
Output:
TLL
POWER SUPPLY
Display/Control unit
12-32 VDC, 55 W
Hull unit
12 or 24/32 VDC, 55 W
(200 W while raising/lowering transducer)
SPECIFICATIONS OF CH-250BB
REMOTE CONTROLLER
(OPTIONAL)
CSH-256
Weight 0.3 kg, 0.7 lb
INTERCONNECTION DIAGRAM
1. Range Scales and Pulse Length
150 kHz
Range
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Meters
10
20
40
60
80
120
160
200
250
300
400
500
600
800
1000
Feet
40
80
120
200
300
400
500
600
700
800
1000
1500
2000
2500
3500
Fathoms
10
20
40
60
80
100
120
140
160
200
250
300
400
500
600
P/B
10
20
40
60
80
100
120
140
160
200
250
300
400
500
700
Time to train full circle
7
7
7
7
7
10
12/13
14/16
16/20
18/24
22/32
26/40
30/48
38/64
46/81
Max scale depends on the system frequency. 1600 m (60 kHz), 1200 m (88 kHz), 1000 m (150 kHz).
Training speed is subject to the system frequency and range scales. Two speeds on long range scales.
EMC AND ENVIRONMENT
Complies with IEC 60945
Display Unit:
-15˚C to +55˚C
Water Resistance: IEC IPX5
EQUIPMENT LIST
Standard
1. Control Head
CH-252
1 Unit
2. Hull Unit CH-254 (travel 400 mm) or
CH-255 (travel 250 mm)
1 Unit
3. Transceiver unit CH-253
1 Unit
4. Installation materials and spare parts
1 Set
5. Interface box IF-8000
1 Unit
6. Motion sensor MS-100 or Clinometer BS-7004
Optional
1. Non-Interlaced, Multi-sync PC Monitor (VGA 640 x 480)
2. Remote controller CH-256
3. Rectifier RU-1746B-2
4. External Speaker
5. 1 m tall steel tank,
1.8 m tall steel tank,
3.5 m tall steel tank,
1 m tall FRP tank,
1.8 m tall FRP tank,
1 m tall aluminum tank
6. NMEAcable
HULL UNIT
CSH-254 (Travel 400 m) 43 kg, 94.8 lb
CSH-255 (Travel 250 m) 42 kg, 92.6 lb
TRANSCEIVER UNIT
CSH-253
Weight 3.2 kg, 7.1 lb
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Furuno USA, Inc. • 4400 NW Pacific Rim Blvd. • Camas, WA 98607 • Tel: (360) 834-9300 • Fax: (360) 834-9400 • www.Furuno.com
INTERFACE UNIT
IF-8000