VHF antennas should be placed in a position which is as elevated and free as
possible, with at least 2 meters horizontal separation from constructions made
by conductive materials.
Ideally there should not be more than one antenna on the same level.
The location of mandatory VHF antennas should be given priority compared
with mobile telephone antennas. If they are located on the same level, the
distance between them should be at least 5 meters.
Isolate the antenna from all metallic parts of the ship.
Current will overflow if the antenna touches any metal part of the ship.
Fabricating the Antenna Connector
Step 1
Strip the RG58 cable according to the dimension in the following figure.
Step 2
Put the antenna connector on the cable orderly.
Step 3
Hold the flange between the insulation and the shield.
Step 4
Tighten the nut.
Step 5
Solder the connector and core.
Wiring
Step 1
Remove the antenna connector cover on the rear back of the unit.
Step 2
Insert the antenna cable into the antenna connector.
Summary of Contents for 9ZWFM4850
Page 1: ...MARINE VHF RADIOTELEPHONE FM 4850 OPERATOR S MANUAL www furuno com Model...
Page 94: ...FM 4850 Operator s Manual INSTALLATION 85...
Page 120: ...FM 4850 Operator s Manual PACKING LIST 111 PACKING LIST...
Page 121: ...PACKING LIST FM 4850 Operator s Manual 112...
Page 122: ...FM 4850 Operator s Manual PACKING LIST 113...
Page 123: ...PACKING LIST FM 4850 Operator s Manual 114...
Page 126: ...FM 4850 Operator s Manual OUTLINE DRAWINGS 117 SP 4800 Desktop mounting Weight 0 76 kg...
Page 127: ...OUTLINE DRAWINGS FM 4850 Operator s Manual 118 SP 4800 Flush mounting Weight 0 76 kg...
Page 128: ...FM 4850 Operator s Manual OUTLINE DRAWINGS 119...
Page 129: ...OUTLINE DRAWINGS FM 4850 Operator s Manual 120...