Furukawa electric S179A Quick Reference Manual Download Page 2

 

 

 

 

S179A Quick Reference Guide 

Select applicable heater program. 

< Fusion Program> 

Tap the fusion program area on the 
touchscreen, or press        key and 
select Fusion Program. 

< Heater Program> 

Select applicable fusion program. 

Open the windshield 
and set the fibers. 
Then enter “Arc Check”. 

Splicer automatically feeds 
the fibers and discharges 
an arc. 

The result is indicated.   
If the result is negative, the 
machine will automatically 
adjust the arc power. Please 
perform the arc check again. 

Procedure for Changing Programs 

Arc Check 

An arc check is the function to adjust the arc power in order to ensure optimal splicing 
results.  Electrode  wear  and  environmental  conditions  such  as  temperature,  humidity, 
and altitude, may affect the arc power. 
Please perform the Arc Check at the beginning of your working day. 

Tap the heater program area on the 
touchscreen, or press        key and 
select Heater Program 