Troubleshooting

 

If you encounter a problem with the appliance as the below table states, first try the suggested solutions. If problems 
persist, please call the service or the dealer. 

 

Don’t repair the appliance by yourself, Repairs must be performed by a certified service technician. 

Problem

Potential cause

Solution

Hot water takes longer 
to reach temperature

1.  Cold water mixing into hot water 

side

2.  Higher Elevation
3.  Incoming water temperature is 

abnormally low incoming water

1.  Check all valves, inside and outside, to ensure they are closed, check shower head 

valve to make sure it is not partially closed.

2.  This is normal due to lesser oxygen levels - Contact Furrion.
3.  See "Water Control Valve" for adjustment.

Low hot water flow at 

the faucet

Lime scale occurs due to 

precipitation of "hard " water.

Decalcify your water heater. See "Cleaning and Maintenance" section.

No hot water at the tap

Gas supply is turned off or 

interrupted.

Check and/or turn on gas supply.

Gas tank is empty.

Refill/replace the gas tank.

The appliance is switched off.

Switch on the appliance according to instructions (“Operating procedures” on page 11).

Fresh water supply is turned off.

Open the fresh water supply.

Power supply to the appliance is 

switched off.

Switch on power supply to the appliance.

Defect in the appliance.

Refer to error codes list on page 15.

Hot water temperature 

too low.

Gas flow to the appliance is too low 

(gas inlet pressure 11in. wc.)

 

Consult vehicle documentation to determine if gas supply is capable of providing 
the necessary volume of gas for the appliance.

 

Contact a service technician to verify a suitable gas installation.

Volume flow of hot water is too high 

and/or the temperature of cold water 

reaching the appliance is too low. 

 

Turn down hot water at the tap or in the shower in order to reduce volume flow. Or 
mix more cold water in faucet.

 

Potentially retrofit a volume flow throttle into the water system. This must be 
performed only by a certified service technician.

Too much lime scale in the appliance. Decalcify your water heater. See "Cleaning and Maintenance" section.

Cold water mixing into Hot water side Check all valves, inside and outside, to ensure they are closed.  Check shower head 

valve to make sure it is not partially closed.

Water escaping at 
pressure safety valve.

Water pressure in water system too 

high.

 

Adjust the water pump pressure to a maximum of 65PSI.

 

If the water system is connected to a central water supply higher than 65PSI (rural 
or urban connection), a water pressure reducer must be used.

 

Install a water pressure regulator at the fresh water supply.

Lime or dirt under the pressure relief 

valve seat.

 

Allow the appliance to cool then slowly operate the relief valve by rotating its valve 
handle(knob), Fig.36) to flush the water system and attempt to force dirt or foreign 
matter out of the pressure relief valve seat. 

 

Replace pressure relief valve. This must be performed only by a certified service 
technician.

Water leaking at the 

water inlet filter.

Lime or dirt under the O-ring seats.

Clean the O-rings and their corresponding sealing surfaces with clean water.

Power status LED is off 

although an operating 

mode was selected.

Power supply to the appliance is 

switched off.

Switch on power supply to the appliance.

Blown fuse.

Switch the standard 125V/10A fuse. Contact Furrion for service.

Water heater stops 

working often and water 

is found on the drainage 

tray.

Unit is overheating, and pressure 

relief valve discharged periodically.

Contact Furrion.

Summary of Contents for FWH09A-AM

Page 1: ...ps furrion com pages downloads climate To view the multi language user manual please access the link or scan the QR code Pour obtenir le manuel d utilisateur multilingue acc dez au lien ou scannez le...

Page 2: ...erator Contact nearest gas supplier or qualified service technician for repairs If you cannot reach a gas supplier or qualified service technician contact the nearest fire department DO NOT turn on ga...

Page 3: ...r inlet and exhaust outlet free of obstructions in order to ensure clean combustion DO NOT place articles on or against the appliance DO NOT lean any objects against the water heater s access door or...

Page 4: ...red output temperature by monitoring key sensors to regulate the thermal energy released over a large heat exchanger This creates a more useful and energy efficient heating system versus the conventio...

Page 5: ...control from surges that may occur when performing Dielectric hi pot testing welding electrical etc work on the coach Only use with a proven 12V power source such as battery or approved converter DO...

Page 6: ...nce are 1 to top surface 0 to all other surfaces NOTE To install on a carpeted area a metal or wood panel that extends at least 3 inches beyond the width and depth of the water heater is required to i...

Page 7: ...cribe a complete system It is the installers responsibility to determine the necessary components for a working system The drawings do not imply compliance with state or local code requirements or reg...

Page 8: ...ating Optional A power switch can be placed in the living quarters for convenience but not required as a switch is located externally on the appliance If the switch is fused make sure it is rated for...

Page 9: ...he mounting flange by a latch Remove the access door and frame from the box separate the components Fig 15 Step 1 separate the access door from the mounting frame Lift the latch and rotate 90 to unloc...

Page 10: ...he sidewall Fig 21 Fig 21 2 Secure the flange to the vehicle using 12 8 min 1 pan head screws not provided through each hole along the perimeter Verify that a tight seal exists between the side wall a...

Page 11: ...ion liquid or equivalent Make certain to re test all fittings after making adjustments to loose connections Failure to follow instruction may lead to serious injury property damage or death 1 Verify t...

Page 12: ...ion 1 Touch button ON OFF to turn the power POWER UP DOWN o F o C ON OFF O F O C FLAME ON OFF Furrion logo on the panel will be illuminated and display the current temperature setting NOTE The micro p...

Page 13: ...r altitudes please contact support furrion com Cleaning and Maintenance WARNING Burn or Scald Hazard NEVER perform work while the water heater is operating NEVER perform work without turning the Elect...

Page 14: ...t tube and screen are completely clear of obstructions including mud leaves twigs insects nest etc Clean by gently breaking up and using a vacuum to clear it Use only water and apply gently from a spr...

Page 15: ...ctive 2 The pressure relief valve is a safety component and must not be removed for any reason other than replacement NOTE The pressure relief valve must be replaced by a certified ser vice technician...

Page 16: ...mechanical sensor faulty System Fault When E3 error displays let cold water flow 10 20S then restart the appliance If E3 still displays contact Furrion E4 Water inlet temperature System Fault Contact...

Page 17: ...hot water is too high and or the temperature of cold water reaching the appliance is too low Turn down hot water at the tap or in the shower in order to reduce volume flow Or mix more cold water in f...

Page 18: ...e LP Gas Inlet Pressure 11 WCI Min to 14 WCI Max Manifold Pressure 0 96 7 6 WCI Power Input 12V DC 3 Amp Water Operating Pressure 10 PSI 65 PSI Orifice mm 1 1 Altitudes 0 2000ft 0 610m Manifold Pressu...

Page 19: ......

Page 20: ...46514 USA Toll free 1 800 789 3341 Email support furrion com 2007 2021 Furrion Ltd Furrion and the Furrion logo are trademarks licensed for use by Furrion Ltd and registered in the U S and other count...

Reviews: