background image

9

SHUTTING DOWN THE SYSTEM

1.  Completely cover system modules with an opaque material to prevent electricity 

from being generated while disconnecting connectors.

2.  Disconnect system from all power sources in accordance with instructions for all 

other components used in the system.

The system should now be out of operation and can be dismantled. In doing so, 
observe all the safety instructions as applicable to installation.

MAINTENANCE

Maintaining Solar Panel

To ensure optimum module performance, Furrion recommends the following 
maintenance measures:

 

Clean the glass surface of the solar panel when required. Always use clean water 
and a soft sponge or cloth for cleaning. A mild, non-abrasive cleaning agent 
may be used to remove stubborn dirt. Do not use cold water to clean panel if the 
surface is extremity hot as rapid temperature change could lead to cracking. 

 

Clean solar panel more frequently during drier months, as they may become 
covered in dust more quickly. A pressure washer is not recommended.

 

Check the electrical, grounding and mechanical connections every six months to 
verify that they are clean, secure, undamaged and free of corrosion.

 

Remove snow, ice, or other debris when build up occurs.

 

Caution: Observe the maintenance instructions for all components used in the 
system, such as support frames, PV connectors, charge controller, inverter, 
batteries, etc.

Long Term RV Storage

If your RV will be stored in extremely cold climates you may need to remove your 
batteries to prevent them from freezing. Please note if your solar panel(s) are covered 
by snow they will not produce power and can not be depended upon to keep the 
batteries charged. For battery storage in mild climates solar system will provide 
more power provided sufficient sunlight and limited load. Make sure that all passive/
phantom loads are removed from the batteries, i.e. DVD players, clock radio, etc. to 
make sure the solar panel(s) can keep the batteries charged even with reduced sun 
exposure.

Summary of Contents for FURRIONNET-ZERO FSFP16MW-BL

Page 1: ...165W RIGID SOLAR PANEL MODEL FSFP16MW BL USER MANUAL Product picture for reference only...

Page 2: ...mation for safe use installation and maintenance of the product Please keep this instruction manual in a safe place for future reference This will ensure safe use and reduce the risk of injury Be sure...

Page 3: ...lar Photovoltaic System 4 MECHANICAL INSTALLATION 5 General Installation Notes 5 Selecting the Mounting Location 5 Selecting the Proper Mounting Structure and Hardware 6 Mounting Methods 6 Secure the...

Page 4: ...read and understood before attempting installation If there are any questions please contact your dealer or Furrion for further information The installer should conform to all safety precautions in t...

Page 5: ...ructures is the responsibility of the system designer and installer Modules may be ground mounted pole mounted or mounted on rooftops Do not attempt to disassemble the module and do not remove any att...

Page 6: ...that are different than those listed in the data sheet Data sheet values are applicable at standard test conditions only Short circuit current and open circuit voltages should be multiplied by a fact...

Page 7: ...structure and hardware must be made of durable corrosion and UV resistant materials Select mounting location such that screw holes on the mounting brackets attached to the solar panel frame are aligne...

Page 8: ...e RV Roof 1 Mount the solar panel through the z brackets sold separately such that at least 2 of the mounting feet have screws penetrating the metal or wooden framing trusses For fixed mounting the po...

Page 9: ...teristics of the solar panel s will vary based on environmental criteria including temperature and solar irradiance To prevent cables and connectors from overheating the cross section of the cables an...

Page 10: ...ore frequently during drier months as they may become covered in dust more quickly A pressure washer is not recommended Check the electrical grounding and mechanical connections every six months to ve...

Page 11: ...h transmission rate and low iron tempered glass 1 8 3 2mm Back TPT Encapsulation material EVA Frame Black Anodized Aluminum Insulation 50M Dimension W x H x D 523 8 x 265 8 x 13 8 1330 x 675 x 35mm We...

Page 12: ...N 46514 USA Toll free 1 800 789 3341 Email support furrion com 2007 2021 Furrion Ltd Furrion and the Furrion logo are trademarks licensed for use by Furrion Ltd and registered in the U S and other cou...