9
Operation
HEAT MODE
NOTE:
The
HEAT
mode is only available
when the furnace is enabled.
●
The system will cycle the furnace
on and off based on the room
temperature and temperature set-
point.
●
There are 4 fan speed selections in
this mode.
●
The fan speed selections only apply
to the rooftop fan that is part of
the Air Conditioner. The fan speed
selection does not change the fan
speed of the furnace.
Low
The fan operates continuously at
low speed and the
icon
displays on the LCD.
Med
The fan operates continuously at
medium speed and the
icon displays on the LCD.
High
The fan operates continuously
at high speed and the
icon displays on the LCD.
Auto
The fan speed varies depending
on the difference between the
temperature set-point and room
temperature. The
icon
displays on the LCD.
OFF The fan is off. The
icon
displays on the LCD.
FAN MODE
●
The temperature set-point is not
available.
●
There are 3 fan speed selections in
this mode.
Low
The fan operates continuously at
low speed and the
icon
displays on the LCD.
Med
The fan operates continuously at
medium speed and the
icon displays on the LCD.
High
The fan operates continuously
at high speed and the
icon displays on the LCD.
DRY MODE
●
Compressor runs continuously
when room temperature is higher
than set-point.
●
Compressor cycles ON for 10
minutes and OFF for 6 minutes
when room temperature is lower
than set-point.
●
The fan speed runs continuously at
low speed.
Set the Temperature
The temperature set-point ranges from
Summary of Contents for FACW12PA-BL