5. Locate the 12VDC power cable (red,
tagged with “+12VDC”) and ground
cable (black, tagged with “Ground
(12VDC)”) of the control box. And
connect them with the corresponding
12VDC wire prepared in the ceiling.
6. Connect the rooftop and freeze sensor
(if purchased) to the control box.
Mounting the Control Box
Install the control box into the mounting
frame and fix with 2 provided “short”
screws (one each side).
3. Locate the four thermostat cables of
the control box (red, green, blue and
purple, which are tied together and
tagged with “To wall thermostat”) and
connect them to the thermostat wire
that extends to the wall.
IMPORTANT:
Note the function
marked on the wire end and carefully trace and mark its function
at the end of the wire extension so that proper connection can be
made at the wall thermostat. If uncertain, perform a continuity test
through each extension to confirm.
4. If applicable, locate the furnace wires from the ceiling controller,
which are two separate brown wires tagged with “FURN”. Connect
them with the 12V+ wire from the
furnace, and the return wire to the
furnace.
NOTE:
Polarity does not matter,
connection can be freely made to
either wire. Do not connect the two
brown “FURN” wires together.
12VDC Power
Cable
Ground Cable
12VDC Wire
from the Ceiling
IG-FHA00032 V1.0
Thermostat Cable
115VAC Power
Cord
115VAC Power
Cord
Furnace Cable
The contents of this manual are proprietary and copyright
protected by Lippert. Lippert prohibits the copying or
dissemination of portions of this manual unless prior written
consent for an authorized Lippert representation has been
provided. Any unauthorized use shall void any applicable
warranty. The information contained in this manual is subject
to change without notice and at the sole discretion of Lippert.
Revised editions are available for free download from
l
ippert.com
.
Please recycle all obsolete materials.
For all concerns or questions, please contact Lippert
PhL 432-LIPPERT (432-547-7378) | Web:
l
ippert.com
|
E-mail:
CCD-0006086 | REV DATE: 10.20.22