Page 1: ...Rooftop Air Conditioner Instruction Manual Model FACR13SA PS FACR13SA BL FACR14SA PS FACR14SA BL FACR15SA PS FACR15SA BL FACT12LA PS FACT12LA BL FACT12SA PS FACT12SA BL Sold Separately ...

Page 2: ...nd maintenance of the product Please keep this instruction manual in a safe place for future reference This will ensure safe use and reduce the risk of injury Be sure to pass on this manual to new owners of this product The manufacturer does not accept responsibility for any damages due to not observing these instructions If you have any further questions regarding our products please contact us a...

Page 3: ...nnecting Cables 10 Installation 11 Installing the Rooftop Unit 11 Installing the Wall Thermostat model FACW12SA BL FACW12PA BL FACW12ZA BL sold separately 11 Installing the Air Distribution Box for FACT12LA PS FACT12LA BL FACT12SA PS FACT12SA BL models only same for both ducted and non ducted models sold separately 12 Troubleshooting 16 Cleaning and Maintenance 17 Specifications 18 Wiring Diagram ...

Page 4: ...be heeded when using electrical devices to protect against Electric shock Fire hazards Injury All Furrion product referenced in this manual is to be installed in accordance with local and national codes including the latest editions of the following standards USA NFPA 1192 NFPA 70 Canada C22 1 CSA Z240 Handling the device WARNING Installation and repair of the rooftop air conditioner must only be ...

Page 5: ... a certified service technician and repaired properly The refrigerant must never be released into the air Handling Electrical Cables WARNING The electrical power supply must only be connected by a qualified electrician CAUTION Refer to NEC National Electric Code for proper sizing of wire gauge awg based on cable length and overcurrent protection rating that is suppling power to the air conditioner...

Page 6: ...apping Screws x 6 Instruction Manual x 1 Warranty Card x 1 Choosing Proper Location for the Air Conditioner IMPORTANT The roof must be designed to support the weight of the rooftop unit and the weight of 2 installers standing on the roof There are two ways of installing the rooftop air conditioner Using the existing roof vent opening in the vehicle roof Making a new opening In this case the openin...

Page 7: ...in the area where the air conditioner will be installed Center Line of Rooftop Front Roof Opening 18 3413 16 884mm 139 16 345mm 279 16 700mm Keep this air flow area free of obstructions Check the inside of the RV for return air kit obstructions i e door openings room dividers curtains ceiling fixtures etc Allow 6 152mm space from the opening to account for any potential return air kit obstructions...

Page 8: ...n authorized service agent Installing in an Existing Opening 1 Unscrew and remove the roof vent 2 Remove all caulking compound around the opening 3 If the opening exceeds 141 4 x 141 4 1 2 it will be necessary to resize the opening to 141 4 x 141 4 1 2 If the opening is less than 141 4 x 141 4 1 2 it must be enlarged 362mm 14 3 6 2 m m 1 4 362mm 14 3 6 2 m m 1 4 Making a new Opening If a roof vent...

Page 9: ...he installer of this system must design the air distribution system for their particular application NOTE Make sure ductwork will NOT bend or collapse during and after installation and that it is correctly insulated and sealed Otherwise damage to roof structure and ceiling could occur The following requirements must be met for properly operate the unit Roof Cavity Depth 3 6 75mm 150mm Duct Cross S...

Page 10: ...ation works best in the most applications It is the responsibility of the installer to review each RV floor plan to determine the following items in conjunction with Air Distribution Duct Sizing and Design section on Page 8 NOTE Alternate configurations and methods may be used which will allow the unit to operate properly however these alternate configurations and methods MUST be approved by Furri...

Page 11: ...icable electrical codes Failure to obey this warning could result in death or serious injury 1 Refer to the applicable electric code guidelines for sizing the appropriate wire gauge length and type 2 Route a 115VAC supply wire with ground wire from the time delay fuse or circuit breaker box to the roof opening NOTE Refer to rooftop unit nameplate and applicable code for proper installation 3 Use a...

Page 12: ...he prepared opening using the gasket at the bottom of the rooftop unit as a guide Fig 1 Roof Opening This Side is Facing Forward Fig 1 This completes the outside installation of the rooftop unit Minor adjustments can be done from inside of the RV if required Installing the Wall Thermostat model FACW12SA BL FACW12PA BL FACW12ZA BL sold separately There are 3 types of wall thermostat for you to sele...

Page 13: ...es Fig 3 Roof Opening Rooftop Unit Cable Ceiling Thickness 115VAC Power Cord 12VDC Wires Fig 3 3 Install the assembled mounting frame and the lower duct divider into the rooftop opening Make sure the THIS WAY FRONT mark is facing front the direction of the vehicle while installing Fig 4 Fig 4 4 Fix the assembled mounting frame and lower duct divider into the rooftop unit using 4 bolts provided Fig...

Page 14: ...ely sealing and duct edges as required 8 Remove the cable compartment cover using a Phillips screw driver Fig 8 Fig 8 DANGER Electrical Shock Hazard Disconnect power before servicing Failure to obey this warning could result in death or serious injury Provide grounding in compliance with all applicable electrical codes Failure to obey this warning could result in death or serious injury 9 Loosen t...

Page 15: ...strip Wall Thermostat Cable Connect to wall thermostat and another zone s control box if applicable See multi zone wiring diagram in page 19 Rooftop Cable Connect to rooftop unit 115VAC Power Cord Connect to 115VAC power source 115VAC Power Cord Wall Thermostat Cable Control Cables from Another Zone s Contol Box Analog Cable Furnace Cable 12V DC Power Cable Room Sensor Cable Freeze Sensor Cable LE...

Page 16: ...nd fix with 4 self tapping screws NOTE Make sure the THIS WAY FRONT mark is facing front the direction of the vehicle while installing Fig 16 Fig 16 19 Align the filter tabs with mating notches and push to snap the filters into the ADB shroud Fig 17 Fig 17 20 Align the decoration plate tabs with the mating notches on the ADB shroud and push to snap the decoration plate into place Fig 18 Fig 18 21 ...

Page 17: ...see the detail contact info at the back page of this manual The air intake grilles are blocked or obstructed Remove any leaves and other dirt from the ventilation grilles of the rooftop air conditioner The blower is defective Contact an authorized service agent or Furrion see the detail contact info at the back page of this manual Water enters the vehicle The condensation water drainage openings a...

Page 18: ...irborne particles and various other factors may result in the filters needing to be cleaned more often 1 Remove the decoration plate from the air conditioning system by pushing the side tabs to release Fig 20 Fig 20 2 Remove the filters by pushing the tabs to release Fig 21 Fig 21 3 The filter can be washed with warm soapy water Care must be taken to avoid ripping the fabric 4 Replace the filters ...

Page 19: ...int h 2 5 2 7 3 2 Applicable vehicle length feet 23 26 31 Refrigerant R410A R410A R410A Charge Oz 15 9 19 8 23 1 Roof top Unit Dimensions L x W x H inch 347 8 x 275 8 x 135 8 347 8 x 275 8 x 135 8 347 8 x 275 8 x 135 8 ELECTRICAL Volts Frequency 115V 60Hz 1Ph 115V 60Hz 1Ph 115V 60Hz 1Ph Power Watts Cooling 1450 1620 1720 Amps Cooling 13 1 14 6 15 4 Power Cord Gauge Min mm2 AWG12 AWG12 AWG12 ...

Page 20: ...ED HIGH MED LOW RY2 ON COM TO UPPER UNIT WHT BK WALL THERMOSTAT B R 12V G TO FURNACE THERM 12V GND GRN YEL WHT RGB LED COIL SENSOR ROOM SENSOR B A 12V GND 6 5 4 3 2 1 115VAC 60Hz 1 BLU BLK YEL RED CN3 CN2 CN6 CN5 CN1 RED BLK BRN BRN ANALOG CONTROL CN8 PASSED DIELECTIC BK RY7 TO UPPER UNIT WHT WHT GAY Elect Heater Optional DANGER Electrical Shock Hazard Disconnect power before servicing Failure to ...

Page 21: ...t 12VDC Input 2 Wires 12VDC Input 2 Wires Air Conditioner Air Conditioner Furrion Thermostat Air Conditioner Room Sensor Indoor Temperature Sensor 115VAC Input Rear Unit Four Conductor Communication Cable Four Conductor Communication Cable Breaker Box Furnace 2 Wires ...

Page 22: ...21 Replacement Parts List 2 1 3 5 9 6 4 7 8 10 11 Rooftop Air Conditioner ...

Page 23: ...4 C FACR15SA 003 Capacitor 5 C FACR15SA 007 Condenser Fan 6 C FACR15SA 006 Condenser Fan Motor 7 C FACR15SA 004 Evaporator Fan Motor 8 C FACR15SA 005 Evaporator Fan 9 C FACR15SA 009 Clip Nut 10 C FACR15SA PS 010 Rooftop Cover White C FACR15SA BL 010 Rooftop Cover Black 11 C FACR15SA PS 011 Screw Cap White C FACR15SA BL 011 Screw Cap Black ...

Page 24: ...23 Replacement Parts List 1 2 3 5 5 4 6 Air Distribution Box ...

Page 25: ...nic Control Box Multi Zone 2 C FACT12SA PS 006 ADB shroud White C FACT12SA BL 006 ADB shroud Black 3 C FACT12SA 004 LED Strip For Electronic Trim kit Right 4 C FACT12SA 005 LED Strip For Electronic Trim kit Left 5 C FACT12SA 003 LED CLIP For Electronic Trim kit 6 C FACT12SA PS 007 Filter White C FACT12SA BL 007 Filter Black ...

Page 26: ...E SURFACE OF PRODUCT TO ANY DATA SOFTWARE OR INFORMATION AND NORMAL WEAR AND TEAR THIS WARRANTY ONLY PROTECTS THE ORIGINAL END USER YOU AND IS NOT TRANSFERABLE ANY ATTEMPT TO TRANSFER THIS WARRANTY SHALL MAKE IT IMMEDIATELY VOID THIS WARRANTY IS ONLY VALID IN THE COUNTRY OF PURCHASE THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS...

Page 27: ...ATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR EXCLUSIONS OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OR CONDITIONS SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE OR WHERE APPLICABLE IN THE COUNTRIES WHERE FURRION HAS NON US CANADIAN AUTHORIZED DEALERS COUNTRY NO ACTION OR CLA...

Page 28: ...echnology 52567 Independence Ct Elkhart IN 46514 USA Toll free 1 888 354 5792 Email support furrion com 2007 2018 Furrion Ltd Furrion and the Furrion logo are trademarks licensed for use by Furrion Ltd and registered in the U S and other countries FURRION COM ...