circuit breaker button!  It is the round black button adjacent to the 
incoming AC cord.  If the circuit breaker trips immediately, there may 
be too great of a current load placed upon it.  Simply disconnect one 
product at a time until this no longer happens.  If the breaker trips 
with no components connected, there may be a wiring defect that 
requires Furman service. 

Indicators

Protection OK Indicator:

Although Furman’s Ground Contamination Free Surge Suppression 
rarely requires servicing, nature has a way of occasionally creating 
electrical  forces  that  are  beyond  the  capabilities  of  any  transient 
voltage  surge  suppressor  device  to  absorb  without  some  degree 
of  damage.  In  the  instance  that  this  occurs,  the  green  “Surge 
Protection” LED indicator will turn off and a warning buzzer will sound 
an audible alarm. If this happens, Furman’s surge suppression circuit 
is compromised. The unit must be returned to Furman Sound, or an 
authorized Furman Service Center for repair. 

Mounting

If the Power Station needs to be mounted to the inside panel of a rack 
or hung from a wall, a convenient crossed oval cutout is provided on 
the unit’s bottom panel.  A standard No. 6 pan head screw can be 
used in the same way a picture is hung from a wall.  Simply measure 
the centers on the bottom of your Power Station.  This will be the 
distance from the two mounting holes drilled into your wall, rack or 
cabinet surface.  Once the screw is fastened fl ush with the surface, 
back it out approximately 1/4”.  The screw head should push through 

Summary of Contents for PST-2+6

Page 1: ...The PST 2 6 Owners Manual...

Page 2: ...l surges and spikes on a daily basis At best these irregularities can degrade your equipment s performance at worst they can severely damage individual components or your entire system Not so with Fur...

Page 3: ...heat registers stoves or other appliances that produce heat 4 The PST 2 6 should only be connected to a 120 VAC 60Hz 15 amp grounded electrical outlet Do not defeat the ground or change polarization...

Page 4: ...the unit without a safety ground is considered improper operation and could invalidate the warranty Operation AC Telephone and Coaxial Connectors Telco Satellite Cable Transient Voltage Surge Suppres...

Page 5: ...hic event If the telephone cable or satellite signal will no longer pass through our protector please send your Power Station to Furman for servicing To test this simply disconnect the incoming and ou...

Page 6: ...degree of damage In the instance that this occurs the green Surge Protection LED indicator will turn off and a warning buzzer will sound an audible alarm If this happens Furman s surge suppression cir...

Page 7: ...does not conform to this Limited Warranty during the warranty period as herein above speci ed Purchaser shall notify Manufacturer in writing of the claimed defects If the defects are of such type and...

Page 8: ...cts upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer THIS WARRANTY IS EXCLUSIVE The sole and exclusive obligation of Manufactu...

Page 9: ...To get an R A number please call the Furman Service Department at 707 763 1010 ext 121 between the hours of 8 00 am and 5 00 pm US Paci c Time When returning equipment for repair please use the origi...

Page 10: ...10...

Page 11: ...11...

Page 12: ...12 Furman Sound Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www FurmanSound com E mail info furmansound com 011104 D...

Reviews: