Furman PS-PRO HT Owner'S Manual Download Page 7

P S - P R O   H T   -   P O W E R   CO N D I T I O N E R / S E Q U E N C E R

OFF sequence. In the REM  position, the PS-PRO 

HT  will  accept  on/off  commands  from  a  remote 

switch or switches that may be connected to the 

rear panel terminals.
CIRCUIT BREAKER: The overall capacity of the PS-

PRO HT is 20 amps. If the combined steady-state 

current  drawn  by  all  devices  plugged  into  all  of 

its nine outlets level exceeds 20 amps at any time, 

the circuit breaker will trip, cutting off power to 

your rack. If this occurs, you must reduce the load 

by unplugging one or more units from the PS-PRO 

HT, and reset it. You can reset the circuit breaker by 

simply pressing in the button, which pops out when 

tripped. However, because it is a thermal type, you 

may have to wait a few moments after it trips for it 

to cool down before it will allow you to reset it.
UNSWITCHED OUTLETS: The PS-PRO HT rear panel 

provides clean, filtered power to this pair of un-

switched outlets, adjacent to the power cord.
SWITCHED  (DELAYED)  OUTLETS: The  PS-PRO  HT 

rear panel provides three pairs of switched outlets, 

widely spaced to allow use of equipment with plug- 

in (wall wart) transformers. These switched outlet 

pairs are labeled Delay 1, Delay 2 and Delay 3. After 

the  front  panel  switch  is  thrown  to  ON,  Delay  1 

outlets receive power instantly, Delay 2 outlets re-

ceive power 1-30 seconds later and Delay 3 outlets 

receive power 1-30 seconds after Delay 2 outlets 

are powered. When thrown to OFF, the sequence is 

reversed, with Delay 3 losing power instantly, Delay 

2 outlets losing power 1-30 seconds  later and Delay 

1 outlets losing power 1-30 seconds after Delay 

2 outlets are shut down. The delay intervals may 

be altered with the screwdriver-adjustable Delay 

Adjust control on the front panel.
TERMINAL STRIP: Allows one or more switches to be 

connected to turn the PS-PRO HT on and off from a 

remote location. Two, and sometimes three, wires 

are needed to install a remote switch (see “Main-

tained Mode”, page 6.) If a four-conductor cable is 

used, an LED may be installed at the remote end to 

indicate that the power is on.

6

REAR PANEL

Summary of Contents for PS-PRO HT

Page 1: ...POWER CONDITIONER SEQUENCER O w n e r s M a n u a l Home Theater Pro Level AC Power Conditioner Sequencer Featuring 3 Channel Sequencing 20 Amp Capac ity Over Voltage Shutdown and Programmable MODEL...

Page 2: ...unswitched outlets one front two rear Ten foot 12 AWG heavy duty power cord Three year limited warranty INTRODUC TION Congratulations on your pur chase of a Furman PS PRO HT Power Conditioner Sequence...

Page 3: ...s the total delay time between the Delay 2 and Delay 3 outlets For example if the Delay Adjust control is set to 30 seconds Delay 1 outlets will go on immediately Delay 2 outlets will receive power 15...

Page 4: ...ront panel in to reset it Although 20 amps is an absolute limit the PS PRO HT will allow you to come as close as possible to using the full 20 amps because with power sequencing the risk of tripping t...

Page 5: ...MP5 spare jumper holder PS PROHTunitscomefactory setformaintained operation jumper is installed on JMP3 They may be easily converted to other operating modes by moving jumper plug plugs on the PS PRO...

Page 6: ...the PS PRO HT will shut down power to all of its switched outlets simultaneously without observing the OFF delay cycle and this LED will begin ashing When power returns to within the acceptable range...

Page 7: ...nt to the power cord SWITCHED DELAYED OUTLETS The PS PRO HT rear panel provides three pairs of switched outlets widelyspacedtoallowuseofequipmentwithplug in wall wart transformers These switched outle...

Page 8: ...e multiple fully loaded PS PRO HTs consult a quali ed electrician If multiple PS PRO HTs are controlled by one or more momentary remote switches all of the PS PRO HTs will change state from on to off...

Page 9: ...ightning is a natural phenomenon of over whelming force that represents the most dif cult circumstance faced by a power protection product The degree of protection a PS PRO HT can offer depends on the...

Page 10: ...ill not be responsible for incidental or consequential damages resulting from the use or misuse of its products Some states do not allow the exclusion of incidental or consequential damages so the abo...

Page 11: ...ch Delays between outlets 3 and 2 and 2 and 1 same as ON delays Remote Switch Screw terminals 2 for switch 2 additional for optional LED 22 ga minimum Spike Protection Modes Line to neutral Clamping V...

Page 12: ...HT POWER CONDITIONER SEQUENCER Furman Sound Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www furmansound com E mail info furmansound com 091...