background image

PM-PRO POWER CONDITIONER/MONITOR

5

Introduction

     Thank you for your purchase of a Furman PM-PRO or PM-PRO-E Power Con-
ditioner / Monitor, and congratulations on your choice. (For simplicity, in this manual
the designation "PM-PRO" refers to either the PM-PRO or the PM-PRO-E unless a
specific distinction is made. A summary of the differences between the two models
appears at the bottom of this page.) The PM-PRO is one of Furman's top-of-the-
line PRO Series power conditioners. It is designed to provide maximum protection
from the types of hazards faced by delicate analog and digital pro audio and video
equipment.

     Your PM-PRO provides the most complete and comprehensive protection from
power line-related transient voltages, noise and wiring faults available. It combines
a high voltage surge and transient suppressor with an RFI/EMI interference filter.
The fast-acting suppression circuit responds in less than a nanosecond, clamping
transient voltages to safe levels. The filter works to prevent noise from fluorescent
lights, certain dimmers, radio transmitters, and similar sources of "electronic pollu-
tion" from contaminating the AC line and from there, leaking into sensitive audio,
video, or computer circuits.

     What sets the Furman Pro Series apart from other conditioners is the quantity,
quality, and configuration of its suppression devices. These include MOV's, gas
discharge tubes, fast-blow fuses, and high voltage inductors and capacitors. This
unique combination can safely absorb and dissipate large spikes from nearby light-
ning strikes and other sources (up to 11,000 amps across any wiring mode -- hot-
neutral, hot-ground, or neutral-ground), as well as highly attenuate audible high
frequency noise. Precise high-inrush magnetic circuit breakers avoid the false trip-
ping often encountered with large reactive loads like power amps.

     The PM-PRO front panel provides a three-color, 20-LED line voltage meter, a
true RMS reading 10-LED AC ammeter, and three status LEDs to indicate abnor-
mal power conditions. The PM-PRO will even keep itself from turning on or shut
down under extreme conditions, if the voltage is below 80 volts or above 140 volts
(below 160 volts or above 280 volts for PM-PRO-E). The front panel also provides
an unswitched outlet (clean, filtered power is provided at the unswitched outlet,
too) and a 20 amp (16 amp for PM-PRO-E) magnetic circuit breaker rated for use
as an on/off switch.

     The rear panel provides eight switched AC outlets to power up all your equipment.
These outlets are spaced widely enough to accommodate up to four bulky plug-
mounted power supplies ("wall warts"). The heavy duty 12 AWG power cord is 10
feet (2.4 m) in length for extra reach and durability on stages and other high-traffic
areas.

PM-PRO Compared to PM-PRO-E

     The PM-PRO is intended for use with 120 VAC power and is rated at 20 amps;
the PM-PRO-E is for 230 VAC power and rated at 16 amps. Outlets on the PM-
PRO-E are IEC-320 types. The GROUND OK feature is not available on the PM-
PRO-E. Other differences concern the reading of the voltmeter and ammeter and
other specifications, which are described on page 8 and on the rear cover.

Summary of Contents for PM-PRO

Page 1: ...FURMAN FURMAN FURMAN FURMAN PRO SERIES Power Conditioner Monitor MODELS PM PRO PM PRO E Owner s Manual 3 9844 1998 FURMAN SOUND INC 960112 1407...

Page 2: ...TVSS rating 400V peak L N 680V peak L G N G 1 nanosecond 11 000 amps 8 x 20mS pulse 550 joules total Differential mode Greater than 40 dB Common mode greater than 60 dB both 1 to 200 MHz 1 75 4 45 cm...

Page 3: ...uctions for future reference 2 The PM PRO should not be used near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement near a swimming pool etc 3 The PM PRO should be s...

Page 4: ...ified service personnel when a The power supply cord or the plug has been frayed kinked or cut b Objects have fallen or liquid has spilled into the unit c The PM PRO has been exposed to rain or other...

Page 5: ...on can safely absorb and dissipate large spikes from nearby light ning strikes and other sources up to 11 000 amps across any wiring mode hot neutral hot ground or neutral ground as well as highly att...

Page 6: ...220V where 120V is expected The PM PRO senses voltages that are so high or low that operation would be impossible and shuts the power down before damage can occur For the PM PRO the cutoff voltages a...

Page 7: ...e power from generators use long extension cords travel internationally or are in an area prone to brownouts you may benefit from the use of one of Furman s AC Line Voltage Regulators LED AMMETER This...

Page 8: ...lowing chart summarizes how the PM PRO s voltmeter responds to input voltages from extremely low to extremely high AC VOLTS 90 100 110 120 128 Mains Below 80V 80 90 90 104 106 108 110 120 122 124 126...

Page 9: ...the actual building where the PM PRO is installed or somewhere very nearby some damage may be unavoid able due to the extremely high voltage and current present If this does occur most likely damage w...

Page 10: ...rization from Furman Furman s liability under this warranty is limited to repair or replace ment of the defective unit Furman will not be responsible for incidental or consequential damages result ing...

Page 11: ...PM PRO POWER CONDITIONER MONITOR 11...

Page 12: ...Voltage Regulator 30A 220 230 240V AC Line Voltage Regulator 30A 24 230 220V N America Use AC Line Voltage Regulator 30A 120V Worldwide Use On Line Uninterruptible Power Supply 1KVA Power Distro 100A...

Reviews: