FURMAN’s PL-PRO DMC FEATURES

SMP

• 

 (Series Multi-Stage Protection) with EVS (Extreme Voltage Shutdown)

LiFT

• 

 (Linear Filtering Technology) with zero ground contamination

Switchable/Dimmable true RMS current and laboratory precise digital voltage meter 

• 

Front panel mounted USB charger

• 

Two 

• 

Smooth Track retractable, long-life, low-heat, front panel LED lights with dimmer-power switch for  rack illumination 

BNC connector on the rear panel accepts  any standard (12VAC 0.5 amp) gooseneck lamp to illuminate the rear of your rack   

• 

(Furman GN-I and GN-LED accessory gooseneck lamps are best for this application)

Eight rear panel AC outlets (three with wide spacing and hook and loop straps to accommodate and secure transformers - wall 

• 

warts)
One front panel convenience outlet

• 

20 amp (2400 watt)

• 

Five year limited warranty

• 

INTRODUCTION

 

Thank you for purchasing a Furman Classic Series power conditioner, and congratulations on your choice. Classic Series power 
conditioners feature Furman’s revolutionary Series Multi-Stage Protection (SMP) circuit, Extreme Voltage Shutdown (EVS), and our 
exclusive Linear Filtering Technology (LiFT).  Together, these technologies comprise precisely what our customers have come to expect 
from Furman - uncompromised AC protection and purification.  Our Classic Series has been precisely engineered to exceed the critical 
demands of audio/video professionals, contractors, broadcasters, and musicians alike.  

SMP (SERIES MULTI-STAGE PROTECTION)

Furman’s SMP surge suppression virtually eliminates service calls and costly “down time”.  Traditional surge suppression circuits sacri-
fice themselves when exposed to multiple transient voltage spikes, requiring the dismantling of your system and repair of your surge 
suppressor.  Not so with Furman’s SMP.  Damaging transient voltages are safely absorbed, clamped, and dissipated.  Your connected 
equipment is protected, while your Furman protects itself!  

 

Unique to Furman’s SMP is its unparalleled clamping voltage, defined as the amount of voltage that is allowed to pass through to your 
equipment when the protection device is subjected to a transient surge or spike.  While other designs offer clamping voltages that are 
well above 330 Vpk, Furman’s SMP clamps at 188 Vpk, (133 VAC RMS) even when tested with multiple 6000 Vpk - 3000 amp surges!  
This unprecedented level of protection is only available with Furman’s SMP technology.  

EVS (EXTREME VOLTAGE SHUTDOWN)

Furman’s trusted over-voltage (EVS) circuitry protects against prolonged overvoltage conditions, such as accidental connections to 208 
or 240 VAC, or an intermittent neutral.  It does so by monitoring the incoming voltage and, when an unsafe condition is detected, 
triggering a relay which shuts off the incoming power until the overvoltage condition is corrected and the power switch is reset.

LIFT (LINEAR FILTERING TECHNOLOGY)

Unfortunately, traditional AC power conditioners have been designed for unrealistic laboratory conditions.  Prior technologies, wheth-
er multiple-pole or conventional series-mode filters, could actually harm audio and video performance more than they help, due to 
the resonant peaking of their antiquated, non-linear designs.  Under certain conditions, these designs can actually add more than 10 
dB of noise to the incoming AC line!  Worse still, lost digital data, the need to reboot digital presets, or destruction of sensitive digital 
converters are frequently caused by excessive voltage spikes and AC noise contaminating the equipment ground.  Furman’s LiFT takes 
a different approach, ensuring optimal performance through linear AC noise filtering with no ground contamination.

PL-PRO DMC ADDITIONAL FEATURES

The PL-PRO DMC features Smooth Track LED rack lights which produce virtually no heat and provide an extremely long lifespan. A dim-
mer control for the rack lights allows the user to adjust the level of illumination (by rotating clockwise/counterclockwise) or switch the 
lamps on and off (by pushing the knob in).  A rear mounted BNC jack accepts any standard (12VAC 0.5 amp) gooseneck lamp for rear 
rack illumination. 

The PL-PRO DMC is equipped with a front panel convenience AC outlet and eight rear panel outlets in two isolated banks. The outlets 
in Bank A are spaced to accommodate transformer plugs (wall warts) which may be secured with the included hook and loop straps. 

Summary of Contents for PL-PRO DMC

Page 1: ......

Page 2: ......

Page 3: ...ALL CONTENT 2008 FURMAN ALL RIGHTS RESERVED PRINTED IN CHINA ENGLISH Page 4 FRANÇAIS Page 10 ESPAÑOL Page 16 PL PRO DMC OWNER S MANUAL PL PRO DMC GUIDE DE L UTILISATEUR PL PRO DMC MANUAL DEL PROPIETARIO ...

Page 4: ...ment when the protection device is subjected to a transient surge or spike While other designs offer clamping voltages that are well above 330 Vpk Furman s SMP clamps at 188 Vpk 133 VAC RMS even when tested with multiple 6000 Vpk 3000 amp surges This unprecedented level of protection is only available with Furman s SMP technology EVS EXTREME VOLTAGE SHUTDOWN Furman s trusted over voltage EVS circu...

Page 5: ... or other appliances that produce extreme heat 4 The Furman PL PRO DMC should only be connected to a 120 VAC 50Hz 60Hz 20 amp grounded electrical outlet Do not defeat the ground or change polarization of the power plug 5 Route the AC power cord and other cables so that they are not likely to be walked on tripped over or stressed Pay particular attention to the condition of the cords and cables at ...

Page 6: ...he PL PRO DMC s outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turning the unit back on without first checking the source of the problem and changing the AC source if necessary PROTECTION OK INDICATOR Although the Furman SMP circuit assures virtually maintenance free protection from transient voltage spikes and surges nature has a way of occa...

Page 7: ...e Shipping charges to Furman headquarters must be prepaid by the purchaser of the product Furman shall at its own expense furnish a replacement product or at Furman s option repair the defec tive product Return shipping charges back to purchaser will be paid by Furman THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED munication devices by ...

Page 8: ...any part thereof whether based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or otherwise shall Furman be liable for incidental special or consequential damages This Limited Warranty states the entire obliga tion of Furman with respect to the product If any part of this Limited Warranty is determined to be void or illegal the remainder...

Page 9: ... outlet dual pull out lamps wall wart spacing for large transformers bnc lamp connector bnc lamp power switch isolated ac outlet banks 10 ft 12 gauge power cable front lamp dimmer meter control button master power switch digital led voltmeter ammeter and status indicators usb charger ...

Page 10: ...surtensions doivent être réparés lorsqu exposés à des pointes de tension transitoires impliquant le démantèlement de votre système Ce n est pas le cas avec le circuit SMP de Furman Les voltages transitoires nuisibles sont absorbés contraints et dissipés de façon sécuritaire Votre équipement branché est protégé tandis que votre appareil Furman se protège lui même Ce qui différencie le circuit SMP d...

Page 11: ...a pluie ou à l humidité Le boîtier comporte des niveaux de tensions élevés Ne retirez pas le couvercle Confiez toujours l entretien à des techniciens qualifiés Le symbole représentant un éclair avec une tête de flèche indique qu il y a présence de tension non isolée dans le boîtier qui dans le cas où sa magnitude est suffisante constitue un risque de choc électrique IMPORTANTES CONSIGNES DE SÉCURI...

Page 12: ... beaucoup de disjoncteurs thermiques moins dispendieux Si la capacité de 20 ampères RMS du PL PRO C est dépassée l interrupteur à ressort se mettra automatiquement en position éteinte Vous devrez remettre l interrupteur en position de marche une fois que le problème sera réglé typiquement vous devrez éliminer une composante ou attendre que le courant RMS n excède pas 20 A ou 2400 watts INDICATEUR ...

Page 13: ...tte gamme est loin d être optimale et pourrait potentiellement endommager certains équipements CHARGEUR USB Le chargeur USB du PL PRO C de Furman constitue une façon pratique de recharger beaucoup d accessoires électroniques popu laires et des appareils de communication cellulaire simplement en branchant le cordon de chargement dans la prise située sur le panneau avant Veuillez prendre note qu il ...

Page 14: ...r à retourner le produit à son siège social Les réclamations sous garantie doivent être accompagnées d une copie de la facture ou du reçu d achat original indiquant la date d achat Les frais d envoi doivent être payés à l avance par l acheteur du produit Furman s engage à remplacer le produit à ses frais ou selon son jugement à réparer le produit défectueux Les frais d envoi à l acheteur seront pa...

Page 15: ...m anodisé noir brossé de 0 120 po circuits imprimés sur verre époxyde CONSOMMATION 15 VA LISTE D AGENCE DE SÛRETÉ TUV convenance prise de courant deux lampes rétractables espacé permettre l utilisation de transformateurs prise de bnc lampe bnc lampe commutateur électrique banques d isolement de sortie à C A 10 pi 12 de mesure de cable électrique gradateur avant de lampe compteur bouton de contrôle...

Page 16: ...icos de voltaje múltiples transitorios que requieren el desmantelamiento de su sistema y la reparación del supresor de sobretensión Esto no sucede con el SMP de Fur man Los voltajes transitorios perjudiciales se absorben se contienen y se disipan con seguridad Su equipo conectado está protegido mientras el SMP de Furman se protege a sí mismo Una característica única del SMP de Furman es el incompa...

Page 17: ...ado El símbolo de relámpa go terminado en flecha sirve para alertar sobre la presencia de voltaje peligroso no aislado dentro del gabinete del equipo y puede tener la suficiente magnitud como para considerarlo un riesgo de descarga eléctrica INSTRUCCIONES IMPORTANTES DE SEGURIDAD Lea las siguientes instrucciones antes de la instalación 1 Lea y respete todas las instrucciones de seguridad y de func...

Page 18: ...enos costosos Si se su pera la capacidad de corriente RMS de 20 amperios del PL PRO C el interruptor con tensión de resorte cambiará inmediatamente a la posición de apagado Usted deberá colocar el interruptor en la posición de encendido nuevamente una vez que se corrija el problema generalmente al eliminar un componente o hasta que la corriente RMS no exceda los 20 amperios o 2400 vatios INDICADOR...

Page 19: ...inda una forma fácil de recargar varios accesorios electrónicos conocidos y dispositivos de comunicación por celular simplemente conectando el cable de recarga en el conector del panel delantero Tenga en cuenta que debido a que actualmente existen muchos estándares para USB es posible que algunos dispositivos no sean compatibles con nuestro cargador Presillas de seguridad para adaptadores de CA to...

Page 20: ...igure la fecha de compra El comprador del producto deberá pagar por adelantado los cargos por el envío a la oficina central de Furman Furman deberá por su propia cuenta proporcionar un producto de reemplazo o bien a su entera discreción reparar el producto defectuoso Furman pagará los gastos de devolución del producto al comprador LA GARANTÍA ANTERIOR SUSTITUYE A TODAS LAS DEMÁS GARANTÍA EXPRE SAS...

Page 21: ... de aluminio anodizado cepillado y negro de 0 120 0 32 cm placas de circuito impreso con vidrio epoxi CONSUMO DE ENERGÍA Aprox 15 VA LISTADO DE LA AGENCIA DE LA SEGURIDAD TUV tomacorriente para servicio dos lámparas retráctiles amplio espacio para enchufar adaptadores de ca conector bnc para la lampara interruptor del conector bnc bancos aislados de los enchufes de ca atenuador de luz botón del co...

Page 22: ...22 PL PRO DMC OWNER S MANUAL Notes ...

Page 23: ...23 FRANÇAIS ENGLISH EspaÑol Notes ...

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com PL PRODMC_RevA ...