Furman PF-Pro R Owner'S Manual Download Page 4

power factor pro manual

6. Clean your Power factor Pro unit with 
a damp cloth only. do not use solvents or 
abrasive cleaners. never pour liquid on or into 
the unit.

7. Your Power factor Pro unit should be 

serviced by qualified service personnel when:

• the power supply cord or the plug has been 

frayed or cut.

• Objects have fallen or liquid has spilled into 

the unit.

• the unit has been exposed to rain or other 

moisture.

• the unit does not appear to operate normally.
• the “Protection oK” indicator is not lit.
• the unit has been dropped, or the enclosure 

has been 

seriously 

damaged.

8. Your Power factor Pro unit requires that a 
safety ground be present for proper operation. 

Any attempt to operate the unit without 

a safety ground is considered improper 
operation and could invalidate the warranty.

  

9. do not attempt to service your Power factor 
Pro unit beyond what is described in this 
manual. all other servicing should be referred 
to qualified service personnel.

f e a t u r e s

the 

Power factor Pro 

has a master switch for 

the rear outlets that glows red when the power 
is on. The circuit breaker is located adjacent to 
the power switch for the Pf-Pro and on the rear 
panel for the Pf-Pro r. it can be quickly and 
easily reset should the unit be overloaded. the 

Pf-Pro 

also features a detachable 10 foot, 14 

gauge heavy-duty power cable. 

the 

Power factor Pro

, offers a 20 segment 

led bar-graph meter that displays incoming 

voltage between 90 and 128 volts in 2-volt 

increments. the normal range voltages are 
indicated in green, with moderately and 
extremely high or low voltages in yellow and 
red respectively. the voltmeter’s accuracy 
is ±2 volts. it can easily be recalibrated, if 
necessary. 

the Pf-Pro r 

features a rear rack BnC 

socket which will accept any 12 VaC (0.5a) 
gooseneck lamp assembly, (such as the 
furman Gn-led or Gn-i).  simply slide the 
BnC plug over the socket and rotate clockwise 
until the connector snaps into the locked 
position.  the rear rack lamp can be powered 
on or off with the rear light power switch 
located on the far left of the front panel.

o P e r at i o n

multi-Segment leD Voltmeter

:

this three-color, 20-led bargraph is an 

accurate, self checking aC voltmeter that 
continually measures input voltages.  the 
meter reads from 90 to 128 volts in 2 volt 
steps (Power factor Pro e: 180 to 256 volts, 
in 4 volt steps).  the normal range voltages 
are indicated in green, with moderate and 
extremely high or low voltages in yellow and 
red respectively.  the voltmeter provides three 
special flashing patterns to indicate abnormal 
conditions. 

(1)  on initial turn on, the voltmeter will 

scan for smart chip integrity.

(2)  if only the single leftmost (beneath 

the 90V mark) LED flashes, the input 

voltage is marginally low. 

3

Summary of Contents for PF-Pro R

Page 1: ...power factor pro manual ...

Page 2: ...lay in a stadium bar or rehearsal space they all have one thing in common the AC power is supplied from your local utility What s worse is that the power factor supplied from your building s AC outlet is typically poor thanks to increasingly over taxed power lines and raised line impedance In fact the quality of AC power has been so poor for so long most musicians have no idea how great their ampl...

Page 3: ...rman Power Factor Pro Power Conditioner please be sure to read this manual carefully before using WAR N I N G To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the covers Refer servicing to qualified personnel only The lightning flash with an arrowhead symbol is intended to alert the user t...

Page 4: ... Pro also features a detachable 10 foot 14 gauge heavy duty power cable The Power Factor Pro offers a 20 segment LED bar graph meter that displays incoming voltage between 90 and 128 volts in 2 volt increments The normal range voltages are indicated in green with moderately and extremely high or low voltages in yellow and red respectively The voltmeter s accuracy is 2 volts It can easily be recali...

Page 5: ...ing faults for example accidental connection to 220VAC where 120VAC is expected or an open neutral from a 208 or 240VAC feed The Power Factor Pro s SMP circuit senses voltages that are so high that operation would be impossible and shuts the power down before damage can occur Upon initially applying power to these units the Extreme Voltage indicator LED will be lit if the input voltage is above th...

Page 6: ...rrants its PF Pro and PF Pro R the Product as follows Manufacturer warrants to the original Purchaser of the Product that the Product sold hereunder will be free from defects in material and workmanship for a period of three years from the date of purchase The Purchaser of the product is allowed fifteen days from the date of purchase to complete warranty registration by mail or on line at the Furm...

Page 7: ...This warranty shall be cancelable by Manufacturer at its sole discretion if the product is modified in any way without written authorization from Furman Sound This warranty also does not apply to Products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer THIS WARRANTY IS EXCLUSIVE The sole and exclusive obligation of Manufact...

Page 8: ...may be used SPECIFICATIONS Current rating 12 amps E versions 7 amps Operating Voltage 90 to 140 VAC E versions 180 to 280 VAC Over Voltage Shutdown 140 VAC typically E versions 280 VAC typically Voltmeter Accuracy 2 VAC calibrated with internal trimpot adjustments Spike Protection Modes Line to neutral zero ground leakage Spike Clamping Voltage 188 Vpk 3 000 amps 133 VAC RMS tested to UL 1449 6 00...