A R - 1 2 1 5    A C   L I N E   V O LTA G E   R E G U L ATO R

convenience outlets on the rear panel, and one on 

the front panel. All are functionally interchangeable. 

The outlets are regulated, spike-suppressed, and fi l-

tered against RFI with a 3-pole fi lter, making the unit 

a full-function power conditioner. The AR-1215 has 

no controls except an on-off switch. (The AR-1215J 

and AR-2306 also have an output voltage selector 

switch.)

Note: The AR-1215 and AR-2306 are for use with 

AC voltage only. DC voltages should never be ap-

plied to them. Also, they do not change or regulate 

line frequency. The output frequency will always be 

the same as the incoming frequency.

MAXIMUM AND MINIMUM LOAD

The AR-1215 and AR-1215J can handle loads total-

ling up to 15 amperes as long as the input voltage 

is equal to or above 124 volts (or 104 volts if using 

AR-1215J set to 100 volt output). For voltages below 

that level, its capacity must be derated at approxi-

mately 113 milliamperes per volt. (See graphs on 

back page.) As a practical matter, therefore, to cope 

successfully with worst-case brownout conditions, 

you should plan your total load so that it does not 

exceed 12 amps, or 1400 watts. Please note that 

this refers to the aggregate power requirement of all 

equipment plugged into the Voltage Regulator, not to 

each individual item.

The AR-2306 can handle loads totalling up to 6 

amperes as long as the input voltage is equal to 

or above the selected output voltage. For voltages 

below that level, its capacity must be derated at ap-

proximately 23 milliamperes per volt. (Again, please 

see graphs on back page.) As a practical matter, 

therefore, to cope successfully with worst-case 

brownout conditions, you should plan your total load 

so that it does not exceed 5 amps, or 1100 watts. 

Please note that this refers to the aggregate power 

requirement of all equipment plugged into the Volt-

age Regulator, not to each individual item.

NOTE: While there is no minimum load require-

ment for the AR1215 or AR-2306, you may 

experience an audible mechanical hum coming 

directly from the unit when the POWER switch 

is on with nothing plugged in. This effect will 

disappear as soon as you plug in any equipment 

A.C. LINE VOLTAGE�

REGULATOR�

MODEL AR-1215 �

INPUT VOLTAGE�

IN�

REGULATION�

EXTREME �

VOLTAG�E�

SHUTDOWN �

REGULATED OUTLET�

POWER�

ON�

OF�F�

 �

75-98�

  � �

W�

A�

R�

N�

I�

N�

G�

FOR CONTINUED �

PROTECTION AGAINST�

FIRE HAZARD REPLACE�

WITH SAME TYPE AND�

RATING OF FUSE�

15 AMP�

100 �V� 120 �V�

75-140 VAC�

REGULATED�

OUTPUTS�

120 VAC�
15 AMPS�

ATTENTION:�

REMPLACER LE FUSIBL�

E�

AVEC MEME TYPE�

DISCONNECT SUPPLY �

BEFORE CHANGING FUSE.�

COUPER L'ALIMENTATION �

AVANT DE CHANGER LE FUSIBL�

E�

6�

A�

M�

P�

220�

OUTPUT VOLTAGE�

230� 240�

CIRCUI� T�

BREAKER�

N’OUVREZ PAS—RISQUE�

DE CHOC ELECTRIQUE�

174-288  VAC          6 � A�

15�

A�

M�

P�

110� 115� 120� 125� 131� 137� 140-150�

105�

101�

15A 120V 50-60HZ�

AR-1215 front view

AR-1215J rear view (the switch above the AC cord is not present in the AR-1215)

AR-2306 rear view. NOTE: The three models in the AR-Series differ in their nominal AC output voltages. Model AR-1215 

produces 120 VAC: AR-1215J produces either 100 or 120 VAC; and AR-2306 produces either 220, 230, or 240 VAC.

3

Summary of Contents for AR-1215

Page 1: ...AC LINE VOLTAGE REGULATOR MODELS AR 1215 AR 1215J AR 2306 AR 121 5 VOLTAGE REGULATORS...

Page 2: ...AR 1215J and AR 2306 only Compact lightweight unit weighs only 12 lbs 5 5 kg SAFETY INFORMATION To obtain best results from your Furman AR 1215 or AR 2306 please be sure to read this manual carefully...

Page 3: ...1215 120 97 to 141 5V AR 1215J 120 97 to 141 4V AR 1215J 100 80 to 122 10V AR 2306 220 174 to 264 10V AR 2306 230 181 to 276 10V AR 2306 240 190 to 288 NOTE The three models in the AR Series differ in...

Page 4: ...that level its capacity must be derated at ap proximately 23 milliamperes per volt Again please see graphs on back page As a practical matter therefore to cope successfully with worst case brownout co...

Page 5: ...age but it can certainly be annoying producing static in audio circuits snow on video screens or garbled data in computers Noise can be introduced into AC lines by nearby radio transmitters certain ki...

Page 6: ...assist in rack power distribution It offers a 20 LED bargraph line voltage meter to moni tor the incoming line the Voltage Regulator output twin slide out swiveling lights with a dimmer control for e...

Page 7: ...arising from improper installation against defects in products or compo nents not manufactured by Manufacturer or against damages resulting from such non Manufacturer made products or components This...

Page 8: ...ode Below 152V or above 287V 230 mode Below 158V or above 300V 240 mode Voltmeter Accuracy AR 1215 and AR 1215J set to 120V 5V AR 1215J set to 100V 4V AR 2306 10V Spike Protection Modes Line to neutra...

Reviews: