TRT800RT / P/N 800ATC-H-(Rxx)-(Rxx)
Operation and Installation
17
Document-No: 03.202.010.71e / Revision: 1.00
3.5 Equipment
Connections
3.5.1 Electrical
Connections
One 9 pin D-SUB miniature connector includes all electrical connections.
3.6 Wiring
3.6.1
Conductor Cross Section
Power Supply (Power, GND):
AWG20 (0,62 mm²)
Signals:
AWG22 (0,38 mm²)
The conductors must be approved for aircraft use. RX and TX should be
shielded individually, or at least be pair-twisted and shielded together.
3.6.2 Pin
Assignment
Pin
Signal
Remarks
1 GND
(Data)
-
2
Data TX
Output
3 -
4 Light
Input
5 UB+
Power
input
6 GND
(Data)
7
Data RX
Input
8 -
-
9 UB+
Power input
(1)
When powering the remote control not by the output of the
switched power output of the remote controlled device but
directly by the aircraft’s power supply, the power input line
(+UB) must be equipped with an external fuse (1Amp./slow).
(1)
UB+: Can be connected to switched power output of
transponder.
Summary of Contents for TRT800RT