Page 1: ...Operation and Installation Document No 03 202 010 71e P N 800ATC H Rxx Rxx TRT800RT OLED Remote Control Unit...

Page 2: ......

Page 3: ...Date Description of Change 1 00 22 10 2012 First Release List of Service Bulletins SB Service Bulletins have to be inserted into this manual and to be enlisted in the following table SB No Rev No Iss...

Page 4: ...ure Flight ID 12 2 6 Transponder Mode selection 13 2 7 Squawk Setting 13 2 8 VFR Squawk 14 2 9 ID Special Position Identification SPI Squawk Ident 14 3 INSTALLATION 15 3 1 Notes 15 3 2 Scope of Delive...

Page 5: ...mechanical and electrical characteristics and about installation and operation of the transponder remote control TRT800RT 1 1 Symbols Advices whose non observance can cause radiation damage to the hum...

Page 6: ...tions Abb Meaning Explanation FID Flight ID Flight plan number or if not assigned registration number of aircraft SPI Special Position Identification Activation on request by controllers Squawk Ident...

Page 7: ...www funkwerk avionics com Any suggestions for improvement of our manuals are welcome Contact service funkwerk avionics com Informations on software updates are available at Funkwerk Avionics 1 4 Feat...

Page 8: ...settings as a result of short time transmission problem e g simultaneous user inputs remote unit settings will be reverted to current transponder setting ON OFF Squawk Ident Activate deactivate VFR C...

Page 9: ...e and standby Squawk works as cursor back button opposite function of the cursor button during entering values and also for navigating backwards through the configuration menu Fehler Verweisquelle kon...

Page 10: ...I O for 0 5 s Switch OFF press I O for 3 s 2 2 1 Display information after power up After turning on the display appears as follows example TRT800RT V1 1 Device Name Software Version Connection to tra...

Page 11: ...ing SPI ID Squawk Ident has been pressed active for 18 s Transponder replies on Mode S Mode A or Mode C interrogations No indication on ADSB and squitter transmission Transponder is locked by a ground...

Page 12: ...y indication are displayed cleared in different time interval or delayed in comparison with TRT800H screen 2 4 Display Brightness In active mode not standby press for 2 s Display indicates DIM Adjust...

Page 13: ...D Press MODE repeatedly until STBY appears Press and hold ID while a counter is shown beside the active squawk Release ID when CHANGE FID is displayed Enter Flight Id with cursor button and rotary kno...

Page 14: ...s are possible apart from Standby AC Mode A C Transponder replies only on Mode A and Mode C interrogations A Mode A Transponder replies only on Mode A interrogations In STBY Standby mode all transpond...

Page 15: ...and activated with In order to store the current active Squawk as new VFR Squawk replacing the factory setting 7000 Press and hold VFR until an S is indicated approx 3 s after releasing the button VFR...

Page 16: ...ircraft Alterations and the appropriate manufacturer s instructions 3 2 Scope of Delivery Item name number Description TRT800RT Remote Header TRT800H Remote Control Unit ATR600RTK3 Connector M4X8ZSW 3...

Page 17: ...uate convection cooling Leave sufficient space for the installation of cables and connectors Avoid sharp bends and wiring close to control cables Leave sufficient lead length for inspection or repair...

Page 18: ...roved for aircraft use RX and TX should be shielded individually or at least be pair twisted and shielded together 3 6 2 Pin Assignment Pin Signal Remarks 1 GND Data 2 Data TX Output 3 4 Light Input 5...

Page 19: ...ment No 03 202 010 71e Revision 1 00 3 7 Post Installation Check All steering and control functions of the aircraft are to be examined in order to exclude disturbances by the wiring A certified mainte...

Page 20: ...o 03 202 010 71e Revision 1 00 3 8 Drawings 3 8 1 Dimensions 3 8 2 Mounting Advices Connector plug has to be clamped with both spring locks New screws may be turned in more than max 15mm into the devi...

Page 21: ...EUROCAE ED 26 RTCA DO 160D RTCA DO 178B Software Level D Temperature Ranges Operation 20 C to 55 C for 30 min 70 C Storage 55 C to 85 C Altitude Range 35 000 ft Shock 6 G Operation 20 G crash safety...

Page 22: ...4 Z No auxiliary cooling required Altitude 4 6 1 C1 35 000 ft Temperature Variation 5 0 C 2 C change rate minimum per minute Humidity 6 0 A Shock 7 0 A 6 G operational shocks 20 G Crash Safety Test Ty...

Page 23: ...ristic DO 160D Section Cat Condition Induced Signal Susceptibility 19 0 A Radio Frequency Susceptibility 20 0 TT Emission of RF Energy 21 0 M Lightning Induced Transient Susceptibility 22 0 B3F3 Light...

Page 24: ...TRT800RT P N 800ATC H Rxx Rxx Operation and Installation 23 Document No 03 202 010 71e Revision 1 00 Notes...

Page 25: ...Funkwerk Avionics GmbH Heinz Strachowitz Str 4 DE 86807 Buchloe Germany phone 49 8241 80066 0 fax 49 8241 80066 99 E mail service funkwerk avionics com www funkwerk avionics com...