 8. General safety instructions

Please read the manual carefully before installaton and setup of your device.
The relevant regulatons must be complied to when working with 230V line voltage, two-wire-

lines, four-wire-lines and ISDN-lines. It is also very important to comply to the regulatons and
safety instructons of working with radio installatons.

Please compl: to the following safet: ruleso

All components may only be mounted and maintained when power is of.

The modules may only be actvated if they are built in a housing and are scoop-proof.

Devices which are operated with external voltage – especially mains voltage – may only be

opened when they have been disconnected from the voltage source or mains.

All connecton cables of the electronic devices must be checked for damage regularly and must

be exchanged if damaged.

Absolutely comply to the regular inspectons required by law according to VDE 0701 und 0702

for line-operated devices.

Tools must not be used near or directly at concealed or visible power lines and conductor paths

and also not at and in devices using external voltage – especially mains voltage – as long as the
power   supply   voltage   has   not   been   turned   of  and   all   capacitors   have   been   discharged.

Electrolytc capacitors can be stll charged for a long tme afer turning of.

When using components, modules, devices or circuits and equipment the threshold values of

voltage, current and power consumpton specifed in the technical data must absolutely be
complied to. Exceeding these threshold values (even if only briefy) can lead to signifcant

damage.

The devices, components or circuits described in this manual are only adapted for the specifed

usage.  If  you  are  not  sure  about  the  purpose  of  the  product,  please  ask your  specialized
distributor.

The installaton and setup have to be carried out by professional personnel.

 9. Returning of old equipment

According to German law concerning electronic devices, old devices cannot be disposed of as regular
waste. Our devices are classifed for commercial use only. According to § 11 of our general terms of

payment and delivery, as of August 2015, the purchasers or users are obliged to return old equipment by us
free   of   cost.   FunkTronic   GmbH   will   dispose   of   this   old   equipment   at   its   own   expense   according   to

regulatons.

Please send old equipment for disposal to:

FunkTronic GmbH

Breitwiesenstr. 4
36381 Schlüchtern

GERMANY

>>> Importanto 

Freight forward deliveries cannot be accepted by us!

Subject to change, errors excepted!

-16-

MBOSVD_eng (24.09.21)

Summary of Contents for Major BOS 4VD

Page 1: ...Major BOS 4VD Major BOS 8VD Manual VoIP control panel for up to 4 8 digital TETRA and or analogous radio terminals...

Page 2: ...OS 8VD 6 3 3 Display standard operaton 8 3 4 Menu control 9 3 5 Major BOS 4VD with opton 4 out of 8 9 3 6 Internal voice redorder 10 4 Connectvity 11 5 Pin layout 12 6 Confguraton via web interface 14...

Page 3: ...jor BOS V devices can also be used with Major BOS 4VD 8VD as there are the footswitch headsets magnetc fxaton for handset metal holder for sunk in table mountng power over ethernet PoE As with all our...

Page 4: ...splay 2 Radio selecton buuons Menu OK 3 Volume display LED band 4 Volume buuons Menu 5 Loudspeaker buuons and special buuons S Men 6 Functon buuons F1 and F2 Go back 7 PTT Menu Escape X 8 Handset with...

Page 5: ...Major BOS 4VD 8VD 3 Control elements Ke pad label Major BOS 4VD 5 MBOSVD_eng 24 09 21...

Page 6: ...Menu OK 3 Volume buuons VOL Menu 4 Volume display LED band 5 Volume buuons VOL Menu 6 Loudspeaker buuons on of Go back 7 Functon F2 programmable 8 Functon F1 programmable 9 PTT X Escape 10 Loudspeake...

Page 7: ...Major BOS 4VD 8VD 3 Control elements Ke pad label Major BOS 8VD 7 MBOSVD_eng 24 09 21...

Page 8: ...e informatons are displayed if the choice of several radios is possible radio with lowest number is displayed Signal Radio Signal Strength Mode of Operaton TMO DMO GW REP Time Current tme as received...

Page 9: ...t the Major and the connected radio SW version serial no IP address connected devices and a possibility to initate a new readout of talkgroups The menu preferences allows to set the display brightness...

Page 10: ...functon is located below the group selecton item Actvaton directly results in replaying the most recent conversaton Navigatng through all recorded calls is possible in a convenient way using the buton...

Page 11: ...s the connecton of two MRTs via ethernet For the connecton of analogous radios the IP interface FT636B is used 2 radios per interface If desired one of the 8 radio circuits can be used to just communi...

Page 12: ...ace programmable I Os external loudspeaker LS2 1 8 1 TXD output 2 RXD input 3 GND 4 I O 1 5 I O 2 6 I O 3 7 AF out LS2 8 AF out GND LS2 Socket PTT Connecton of ext PTT e g foot switch or headset adapt...

Page 13: ...hone 5 GND AF in mic 6 GND PTT HS1 Socket S E 8 wire socket for connecton of analogous device 1 8 1 NF in A 2 NF in B 3 SQL in S E with Pullup 4 GND 5 BATT out Do not connect to radio 6 PTT S E in out...

Page 14: ...update 9999 TCP protocol Please be aware that all devices that need to be connected have to be in the same subnet 6 1 Restoring the default IP address If the IP address of the Major BOS 4VD 8VD is no...

Page 15: ...nge 99 dB bis 26 dB 200 Ohm Input impedance 600 Ohm Output level S E Factory setng 500 mV 3 8 dB 200 Ohm Adjustment range 99 dB bis 26 dB Output impedance ca 200 Ohm Output level for earphone headset...

Page 16: ...as the power supply voltage has not been turned of and all capacitors have been discharged Electrolytc capacitors can be stll charged for a long tme afer turning of When using components modules devi...

Page 17: ...ase notes 15 11 17 frst version for Major BOS 8VD 23 07 18 enhanced manual for Major BOS 4VD and Major BOS 8VD 06 11 20 correcton of pin layout socket RS232 minor changes 24 09 21 additon of voice rec...

Reviews: