Tone Table
Tone ZVEI 1
CCIR
ZVEI 2
EEA
ZVEI 3
0
2400 Hz
1981 Hz
2400 Hz
1981 Hz
2200 Hz
1
1060 Hz
1124 Hz
1060 Hz
1124 Hz
970 Hz
2
1160 Hz
1197 Hz
1160 Hz
1197 Hz
1060 Hz
3
1270 Hz
1275 Hz
1270 Hz
1275 Hz
1160 Hz
4
1400 Hz
1358 Hz
1400 Hz
1358 Hz
1270 Hz
5
1530 Hz
1446 Hz
1530 Hz
1446 Hz
1400 Hz
6
1670 Hz
1540 Hz
1670 Hz
1540 Hz
1530 Hz
7
1830 Hz
1640 Hz
1830 Hz
1640 Hz
1670 Hz
8
2000 Hz
1747 Hz
2000 Hz
1747 Hz
1830 Hz
9
2200 Hz
1860 Hz
2200 Hz
1860 Hz
2000 Hz
A
2800 Hz
2400 Hz
886 Hz
1055 Hz
886 Hz
B
810 Hz
930 Hz
810 Hz
930 Hz
810 Hz
C
970 Hz
2247 Hz
740 Hz
2247 Hz
740 Hz
D
886 Hz
991 Hz
680 Hz
991 Hz
680 Hz
E
2600 Hz
2110 Hz
970 Hz
2110 Hz
2400 Hz
length
min. 52.5 msec 75
msec 52.5 msec 30 msec 52.5 msec
typ.
70
msec 100 msec 70 msec 40 msec 70 msec
max. 87.5 msec 125 msec 87.5 msec 50 msec 87.5 msec
Transmitter keying
The transmitter can be keyed by the red PTT button on the key pad. The transmitter is keyed as long
as the PTT button is pressed, except if the TX time out is exceeded. In the multi wire version it is
controlled by an open collector output and in AC version by a pilot tone.
TX time out timer
The TX time out timer is programmed in one second intervals at positions 1 to 3 of register
051. Values of '000' up to '255' are permitted. If the programmed value is '000', the TX time
out timer is out of operation.
Transmitter prerunning time
The prerunning time is preceding every call before connecting the audio. It can be programmed
in 10 msec intervals at positions 1 to 2 of register 052. The variable value can be defined freely
between '00' and '99'.
PTT button blocking
The PTT button blocking is programmed at position 5 of register 052.
0 = PTT button blocking is switched off
1 = PTT button is blocked in case of sensed carrier