FunkTronic FT638 Manual Download Page 17

FT638 – Digital Radio Box

 10.General Safety Instructons

 10. General Safety Instructions

Please read the manual carefully b efore installaton and setup of your device.
The relevant regulatons must b e complied to when working with 230V line voltage, two-wire-

lines, four-wire-lines and ISDN-lines. It is also very important to comply to the regulatons and
safety instructons of working with radio installatons.

Please comply to the following safety rules:

All components may only b e mounted and maintained when power is of.

The modules may only b e actvated if they are b uilt in a housing and are scoop-proof.

Devices which are operated with external voltage – especially mains voltage – may only b e

opened when they have b een disconnected from the voltage source or mains.

All connecton cab les of the electronic devices must b e checked for damage regularly and must

b e exchanged if damaged.

Ab solutely comply to the regular inspectons required b y law according to VDE 0701 und 0702

for line-operated devices.

Tools must not b e used near or directly at concealed or visib le power lines and conductor paths

and also not at and in devices using external voltage – especially mains voltage – as long as the
power   supply   voltage   has   not   b een   turned   of  and   all   capacitors   have   b een   discharged.

Electrolytc capacitors can b e stll charged for a long tme afer turning of.

When using components, modules, devices or circuits and equipment the threshold values of

voltage, current and power consumpton specified in the technical data must ab solutely b e
complied to. Exceeding these threshold values (even if only b riefy) can lead to significant

damage.

The devices, components or circuits describ ed in this manual are only adapted for the specified

usage.  If you  are not   sure ab out  the  purpose  of  the product,  please  ask  your  specialized
distrib utor.

The installaton and setup have to b e carried out b y professional personnel.

 11. Returning of Old Equipment

According to German law concerning electronic devices, old devices cannot b e disposed of as regular
waste. Our devices are classified for commercial use only. According to § 11 of our general terms of

payment and delivery, as of August 2015, the purchasers or users are ob liged to return old equipment b y us
free   of   cost.   FunkTronic   Gmb H   will   dispose   of   this   old   equipment   at   its   own   expense   according   to

regulatons.

Please send old equipment for disposal to:

FunkTronic GmbH

Breitwiesenstrl 4
36381 Schlüchtern

GERMANY

>>> Important: 

Freight forward deliveries cannot b e accepted b y us!

Subject to change, errors excepted!

-17-

FT638_eng (29.04.22)

Summary of Contents for FT638

Page 1: ...FT638 Digital Radio Box Manual...

Page 2: ...oard configuraton 11 6 1 RS232 levels connecton of MRT1 MRT2 11 6 2 SQL configuraton connectors A1 A2 11 6 3 BUSY or 12V Connectors A1 A2 12 6 4 Solder b ridges b ack of PCB 12 7 PEI multplexer 13 7 1...

Page 3: ...vely DMR Motorola DM4000 series Kenwood NX5000 series Hytera MD785 series For TETRA operaton the FT638 also allows for b idirectonal PEI AT access of additonal applicatons via its internal PEI AT mult...

Page 4: ...via FT protocol 638092 Opton EXTENDED PEI AT access via ethernet 4x access via FT protocol 638093 Opton FULL PEI AT access via ethernet complete access via FT protocol 638900 Connecton cab le FT638 to...

Page 5: ...els operaton control sofware In the standard version one additonal connector per MRT is availab le For MRT1 this is a standard 9 pin COM socket If a third party device is to b e connected here the cab...

Page 6: ...s the standard version the FT638 can also b e ordered as IN OUT version Here up to 3 PEI AT partcipants can b e connected to one MRT in additon to voice over IP partcipants Hence the connector MRT2 is...

Page 7: ...put 11 RS232_TXD output 12 RS232_RTS output 13 RS232_CTS input 14 RS232_DTR output 15 GND Connector MRT2 PEI Out only for TETRA IN OUT version Connecton of TETRA applicatons audio PEI AT 1 CONS_TXD in...

Page 8: ...Connecton of additonal PEI AT partcipants for MRT2 if STD Version for MRT1 if I O Version and programmab le I Os 1 8 1 TXD output 2 RXD input 3 GND 4 I O 0 5 I O 1 6 I O 2 7 I O 3 8 I O 4 Connectors A...

Page 9: ...work 1 ETH1 Local IP address 192 168 16 191 Target IP VoIP 1 192 168 16 192 Sub net mask 255 255 255 0 Audio AF port 10000 UDP Data port 10001 TCP Web server port 80 TCP IP network 2 ETH2 Local IP add...

Page 10: ...e IP address of the device For this each numb er is BCD coded and displayed for two seconds LED A represents the most significant b it As a delimiter b etween the groups of three digits all 4 LEDs are...

Page 11: ...B Ex factory on incoming transmissions SQL switches to 12V JP1 A for connector A1 Pin 1 2 connected SQL to 12V Pin 2 3 connected SQL to GND JP1 B for connector A2 Pin 4 5 connected SQL to 12V Pin 5 6...

Page 12: ...e its BUSY output would b e destroyed 6 4 Solder bridges back of PCB In order to connect a Sepura console via FT638 IN OUT version the two solder b ridges on the b ackside of the b oard have to b e cl...

Page 13: ...l panels e g Major BOS 4VD 8VD one more PEI AT partcipant can b e connected to the FT638 see as well 3lInterfaces and 4lPin layout Opton ACCESS or higher is needed if using the PEI AT interfaces of b...

Page 14: ...ry Parameter 8084 Product Product Specific Hardware Accessories Audio Presentaton Gain Setng for Line In Audio to 30 dB standard gain setng Parameter 8080 Product Product Specific Hardware Accessories...

Page 15: ...udrate 38400 FT638 standard can b e configured diferently if necessary Move RS232 from DB9 to Motorola Accessory Connector Must b e actvated if a MTM800 FuG MTM5X00 without 9 pin COM connector is to b...

Page 16: ...ca 520 g Dimensions W x D x H 105mm x 140mm x 44mm MRT1 2 Input impedance 1 kOhm Output impedance 200 Ohm Input level max 2 dBm Output level max 2 dBm A1 2 Input impedance 1 kOhm Output impedance 200...

Page 17: ...g as the power supply voltage has not b een turned of and all capacitors have b een discharged Electrolytc capacitors can b e stll charged for a long tme afer turning of When using components modules...

Page 18: ...er remarks ab out PEI multplexer functonality product versions with new functonalites added configuraton for voltage supply BUSY on connectors A1 A2 added 06 02 19 descripton of solder b ridges on the...