- 12 -
ft634a (23.06.2009)
Kompetent für Elektroniksysteme
- 13 -
ft634a (23.06.2009)
Kompetent für Elektroniksysteme
The screen for potentiometer 1:
(The actual reading of the internal reference value iis shown after changing or blank key.)
Adjustment potentiometer 1:
Feed with required level into line-input at 1000Hz.
Adjust ‚Line‘ to 300mV at internal reference value.
Initial value: adjustment potentiometer 1:
Feed with required level into line-input at 1000Hz.
Adjust ‚Line‘ to 300mV at internal reference value.
Initial value: 014 (min:000 max:255) level: 000 mV reference value:
300 mV
Keys: <+> : +1
<*> : +10
<-> : -1
<_> : -10
< > : measuring only
<a> : self-adjustment
<p> : programming
<x> : cancel
The screen for potentiometer 2:
Adjustment potentiometer 2:
Feed with required level at line-input at 3400Hz.
Adjust ‚Line‘ to 300mV at internal reference value.
Initial value: 057 (min:000 max:255) level: 000 mV required value:
300 mV
Keys: <+> : +1
<*> : +10
<-> : -1
<_> : -10
< > : measuring only
<a> : self-adjustment
<p> : programming
<x> : cancel
The screen for potentiometer 3:
Adjustment potentiometer 3:
Feed with required level at line-input at 1000Hz.
Adjustment pot 1 and 2 (reference value ‚Line‘ = 300mV).
Adjustment radio-output at required value (required modulation
depth).
Initial value: 015 (min:000 max:255)
Keys: <+> : +1
<*> : +10
<-> : -1
<_> : -10
<t> : transmitter on/off
<p> : programming
<x> : cancel
The screen for potentiometer 4:
Adjustment potentiometer 4:
Feed at radio input with required level at 1000Hz.
Adjust at internal reference value ‚Radio‘ to 300mV.
Initial value: 160 (min:000 max:255) level: 000 mV required value:
300 mV
Keys: <+> : +1
<*> : +10
<-> : -1
<_> : -10
< > : measuring only
<a> : self-adjustment
<p> : programming