12. Cut-off Adjustment
Purpose: To adjust the beam current of R, G, B, and
screen voltage.
Symptom of Misadjustment: White color may be red-
dish, greenish or bluish.
Test Point
Adj. Point
Mode
Input
---
Screen-Control
CH
▲
/
▼
buttons
RF
Black
Raster
Tape
M. EQ.
Spec.
---
Pattern Generator
See Reference
Notes below.
Figure
Note: Screen Control FBT --- Main CBA
F.B.T= Fly Back Transformer
Use Service remote control unit
1. Degauss the CRT and allow CRT to operate for 20
minutes before starting the alignment.
2. Input the Black Raster Signal from RF Input.
3. Enter the Service mode. (See page 5-1)
4. Press " VOL
▼
" button on the Service remote
control unit and select " C/D " mode. (Display
changes " C/D ", "VCO ", " 7F " and " FRENCH "
cyclically when " VOL
▼
" button is pressed.) then
press " 1 ". The display will momentarily show " CUT
OFF R " (R= Red). Now there should be a horizontal
line across the center of the picture tube. If needed
gradually turn the screen control on the flyback,
clockwise until the horizontal line appears. Adjust
the Red Cut off by pressing the " CH
▲
/
▼
" buttons.
Proceed to Step 5 when the Red Cut off adjustment
is done.
5. Press the " 2 "button. The display will momentarily
show " CUT OFF G " (G=Green). Adjust the Green
Cut off by pressing the " CH
▲
/
▼
" buttons. Proceed
to step 6 when the Green Cut off adjustment is done.
6. Press the " 3 " button. The display will momentarily
show " CUT OFF B " (B=Blue). Adjust the Blue cut
off by pressing the " CH
▲
/
▼
" buttons. When done
with steps 4, 5 and 6 the horizontal line should be
pure white if not,then attempt the Cut off adjustment
again.
13. White Balance Adjustment
Purpose: To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment: White becomes bluish
or reddish.
Test Point
Adj. Point
Mode
Input
Screen
CH
▲
/
▼
buttons
RF
White
Raster
(APL 100%)
Tape
M. EQ.
Spec.
Pattern Generator,
Color analyzer
See below
Figure
Note: Use Service remote control unit
1. Operate the unit more than 20 minutes.
2. Face the unit to east. Degauss the CRT using De-
gaussing Coil.
3. Input the White Raster (APL 100%).
4. Set the color analyzer to the CHROMA mode and
after zero point calibration, bring the optical receptor
to the center on the tube surface (CRT).
5. Enter the Service mode . Press " VOL
▼
" button on
the Service remote control unit and select " C/D "
mode. (Display changes " C/D ", "VCO ", " 7F " and
" FRENCH " cyclically when " VOL
▼
" button is
pressed.) then Press No. 8 button on the Service
remote control Unit.
6. Press No. 4 button on the service remote control unit
for Red adjustment. Press N0. 5 button on the
Service remote control unit for Blue adjustment.
7. In each color mode, Press " CH
▲
/
▼
" button to
adjust the values of color.
8. Adjusting Red and Blue color so that the tempreture
becomes 9200K (x : 286 / y : 294)
±
3%.
9. At this time, Re-check that Horizontal line is white.
If not, Re-adjust Cut-off Adjustment until the Hori-
zontal Line becomes pure white.
10. Turn off and on again to return to normal mode.
Receive APL 100% white signal and Check Chroma
temperatures become 9200K (x : 286 / y : 294)
±
3%.
Note: Confirm that Cut Off Adj. is correct after this
adjustment, and attempt Cut Off Adj. if needed.
AAA
Color Analyzer
Fig. 3
PATTERN GENERATOR
RF INPUT
Fig. 2
5-5
L1300EA
Summary of Contents for SYLVANA 6413TB
Page 9: ...IF SIGNAL VIDEO SIGNAL AUDIO SIGNAL...
Page 12: ...VIDEO SIGNAL...
Page 18: ...6413TB TVK131 W6413TB L1302UC 06UG 08UJ Printed in Japan 2001 03 30 HO...
Page 19: ...SERVICE MANUAL 13 COLOR TELEVISION ST413B...
Page 46: ...IFSIGNAL VIDEO SIGNAL AUDIO SIGNAL...
Page 49: ...VIDEO SIGNAL...
Page 69: ...ST413B L1300UA Printed in Japan 2001 01 31 HO...