5-2
A03A0EA
2. Auto Calibration [Component]
Purpose:
To bring the color adjustment of each
component into standard alignment.
Symptom of Misadjustment:
If this adjustment is
incorrect, component signals do not reproduce the
corresponding color.
1. Input 720P 100% Color Bar signal.
2. Enter the service mode.
3. To enter the Auto Calibration adjustment mode,
press [6] button on the service remote control unit.
4. To start auto adjustment, press [P
] button on the
service remote control unit.
- In the auto adjustment mode, “Calibration Check”
appears on the screen.
- Upon completion, “OK” appears on the screen.
5. To cancel or to exit from the Auto Calibration
[Component], press [BACK] button.
3. Auto Calibration [PC]
Purpose:
To bring the color adjustment of PC into
standard alignment.
Symptom of Misadjustment:
If this adjustment is
incorrect, PC signals do not reproduce the
corresponding color.
1. Input SVGA 100% White signal.
2. Enter the service mode.
3. To enter the Auto Calibration adjustment mode,
press [5] button on the service remote control unit.
4. To start auto adjustment, press [P
] button on the
service remote control unit.
- In the auto adjustment mode, “Calibration Check”
appears on the screen.
- Upon completion, “OK” appears on the screen.
5. To cancel or to exit from the Auto Calibration [PC],
press [BACK] button.