6-4
A73F2EA
he following adjustment normally are not
attempted in the field. Only when replacing the
LCD Panel then adjust as a preparation.
5. White Balance Adjustment
*This adjustment is needed when reparing T-CON
CBA.
Purpose:
To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment:
White becomes bluish
or reddish.
1. Operate the unit for more than 20 minutes.
2. Input the White Purity.
3. Set the color analyzer to the CHROMA mode and
bring the optical receptor to the center on the
LCD-Panel surface after zero point calibration as
shown above.
Note:
The optical receptor must be set
perpendicularly to the LCD Panel surface.
4.
[CVBS]
Enter the Service mode. Press [
-] button on the
remote control unit and select “C/D/S 1” mode.
[YUV]
Enter the Service mode. Press [
-] button on the
remote control unit and select “C/D/S 2” mode.
[RGB]
Enter the Service mode. Press [
-] button on the
remote control unit and select “C/D/S 3” mode.
5.
[CVBS]----(APL 70%)
Press [6] button to select “DB 1(C/D/S 1)” for Blue
adjustment. Press [4] button to select “DR 1(C/D/S
1)” for Red adjustment. When “x” value and “y”
value are not within specification, adjust “DB 1(C/
D/S 1)” or “DR 1(C/D/S 1)”. Refer to “1. Initial
Setting.”
[CVBS]----(APL 30%)
Press [3] button to select “COB 1(C/D/S 1)” for
Blue adjustment. Press [1] button to select “COR
1(C/D/S 1)” for Red adjustment. When “x” value
and “y” value are not within specification, adjust
“COB 1(C/D/S 1)” or “COR 1(C/D/S 1)”. Refer to
“1. Initial Setting.”
After adjusting (APL 30%), verify (APL 70%) again
and adjust repeatedly until both values are within
specification.
6.
[YUV]----(APL 70%)
Press [6] button to select “DB 2(C/D/S 2)” for Blue
adjustment. Press [4] button to select “DR 2(C/D/S
2)” for Red adjustment. When “x” value and “y”
value are not within specification, adjust “DB 2(C/
D/S 2)” or “DR 2(C/D/S 2)”. Refer to “1. Initial
Setting.”
[YUV]----(APL 30%)
Press [3] button to select “COB 2(C/D/S 2)” for
Blue adjustment. Press [1] button to select “COR
2(C/D/S 2)” for Red adjustment. When “x” value
and “y” value are not within specification, adjust
“COB 2(C/D/S 2)” or “COR 2(C/D/S 2)”.
Refer to “1. Initial Setting.”
After adjusting (APL 30%), verify (APL 70%) again
and adjust repeatedly until both values are within
specification.
7.
[RGB]----(APL 70%)
Press [6] button to select “DB 3(C/D/S 3)” for Blue
adjustment. Press [4] button to select “DR 3(C/D/S
3)” for Red adjustment.When “x” value and “y”
value are not within specification, adjust “DB 3(C/
D/S 3)” or “DR 3(C/D/S 3)”. Refer to “1. Initial
Setting.”
[RGB]----(APL 30%)
Press [3] button to select “COB 3(C/D/S 3)” for
Blue adjustment. Press [1] button to select “COR
3(C/D/S 3)” for Red adjustment. When “x” value
and “y” value are not within specification, adjust
“COB 3(C/D/S 3)” or “COR 3(C/D/S 3)”.
Refer to “1. Initial Setting.”
After adjusting (APL 30%), verify (APL 70%) again
and adjust repeatedly until both values are within
specification.
8. Turn the power off and on again.
Test Point Adj. Point
Mode
Input
Screen
[
-]
button
[CVBS]
C/D/S 1
[YUV]
C/D/S 2
[RGB]
C/D/S 3
White Purity
(APL 70%)
or
(APL 30%)
M. EQ.
Spec.
Pattern Generator,
Color analyzer
(APL 70%)
x= 0.272 ± 0.03,
y= 0.278 ± 0.03
(APL 30%)
x= 0.272 ± 0.01,
y= 0.278 ± 0.01
Figure
Color Analyzer
It carries out in a darkroom.
L = 3 cm
Perpendicularity
INPUT: WHITE 70%, 30%
30%=30IRE
70%=70IRE
INPUT SIGNAL
Summary of Contents for LT5-M32BB
Page 1: ...SERVICE MANUAL 32 COLOR LCD TELEVISION LT5 M32BB...
Page 36: ...8 7 Jack 1 2 Schematic Diagram A73F2SCJ1...
Page 37: ...8 8 A73F2SCJ2 Jack 2 2 Schematic Diagram...
Page 39: ...8 10 IR Sensor Schematic Diagram A73F2SCIR...
Page 40: ...8 11 Digital Main 1 6 Schematic Diagram A73F2SCD1...
Page 43: ...8 14 Digital Main 4 6 Schematic Diagram A73F2SCD4...
Page 48: ...8 19 BA73F0F01032 Jack CBA Top View...
Page 52: ...8 23 Function CBA Top View Function CBA Bottom View BA73F0F01022 2...