8-6
A93N2BLP
Power Supply Block Diagram
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
HO
T
COLD
MAIN CB
A
HOT CIRCUIT. BE CAREFUL.
Q602
SWITCHING
CONTR
OL
1
4
3
2
IC605
T601
5
LINE
FIL
TER
L601
AC
6
0
1
A
C CORD
BRIDGE
RECTIFIER
D602, D604, D605, D607
3
4
19
18
17
16
15
14
13
12
7
8
FEED
BA
CK
Q601
SWITCHING
Q603
CN301
CN302
CN3701
LCD MODULE ASSEMBLY
Q612, Q613
SWITCHING
Q611
SW
-6.8V
Q604
Q607
Q616
SW+5V
Q605
Q609
SW+11V
Q615
SW+13V
Q606,D671
SW+3.3V
SW+3.3V
F601
T4A H 250V
P-ON-H1
T
O SYSTEM
CONTR
OL
BLOCK
DIA
GRAM
P-ON-H2
PROTECT1
Q610
P-ON+5V
AL+3.3V
AL+15V
P-ON+11V
13-16
10
27-29
AL+3.3V(1)
AL+5V
AL+3.3V
P-ON+3.3V
P-ON+5V
DIGIT
AL MAIN CB
A UNIT
P-ON+3.3V
13-16
P-ON+3.3V
6,7
P
ANEL+24V
4
LCD-6.8V
8
P
ANEL+13V
2,3
AL+3.3V
10
24,26
19-21
AL+5V
24,26
AL+3.3V(1)
19-21
P-ON+5V
27-29
AL+33V
Summary of Contents for LH7-M19BB
Page 13: ...4 2 A93N2DC 2 Rear Cabinet 1 Stand Assembly S 3 S 2 S 2 S 2 S 2 S 2 S 4 S 4 S 1 Fig D1...
Page 35: ...9 4 A93N2SCM2 Main 2 4 Schematic Diagram...
Page 36: ...9 5 A93N2SCM3 Main 3 4 Schematic Diagram...
Page 37: ...9 6 A93N2SCM4 Main 4 4 Schematic Diagram...
Page 38: ...9 7 A93N2SCF Function Junction Schematic Diagram...
Page 42: ...9 11 A93N2SCD4 Digital Main 4 7 Schematic Diagram...
Page 68: ...LH7 M19BB A93N2EP 2009 07 23...