1-11-18
BE2B00F01022
Power Supply CBA Bottom View
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F2001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
Summary of Contents for HD-A2685
Page 1: ...SERVICE MANUAL HDD DVD RECORDER HD A2685 HD A2885 HD B2785 HD D2885 ...
Page 29: ...1 11 6 E2B25SCAV4 AV 4 5 Schematic Diagram ...
Page 30: ...1 11 7 E2B25SCAV5 AV 5 5 Schematic Diagram ...
Page 38: ...1 11 15 AV CBA Top View BE2B20F01042A ...