5-1
FL10.2EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note: “CBA” is abbreviation for
“Circuit Board Assembly.”
Note:
Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White
Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)
2. Remote control unit
3. Color Analyzer
How to set up the service mode:
Service mode:
1. Turn the power on.
2. Press [MENU] button to display Setup menu.
3. Select “Features”.
4. Select “Current Software Info”.
5. Press [0], [4], [2], [5], [7], [4] and [INFO] buttons on
the remote control unit in this order. The following
screen appears.
Code :
Pic code :
MIPS :
Press "POWER" key to exit.
******-***-*-***-****
**-*******-***-*-***
Push 0 key
Tuner :
Safety :
HDMI EDIT :
****-*****-****
safety_Non
OK
"*" differs depending on the models.
Summary of Contents for Emerson LC260EM1
Page 41: ...10 4 FL10 2SCM2 Power Supply 2 Schematic Diagram...
Page 42: ...10 5 FL10 2SCM3 Power Supply 3 Jack Schematic Diagram...
Page 43: ...10 6 FL10 2SCM4 Power Supply 4 Schematic Diagram...
Page 44: ...10 7 FL10 2SCINV Inverter Junction B Schematic Diagram...
Page 45: ...10 8 FL10 2SCF Function Junction A Schematic Diagram...